2. System Description
11
© 2007 Moseley, Inc. All Rights Reserved.
602-14886-01, Rev. A
Table 2-3. DVB-ASI Input status LED.
LED
STATUS
GREEN
Good ASI input
RED
No ASI input
Alternating
YELLOW/GRN
ASI exceeds radio bit rate
(FIFO overflow)
Flashing RED
Loss-of-Frame
Flashing GRN
No ASI data
Table 2-4. DVB-ASI Output status LED.
LED
STATUS
GREEN
Active Locked ASI Link
Alternating
RED/GREEN
No ASI, loss-of-frame
GREEN,
occasionally
flashing YELLOW
Locked ASI link with errors
(yellow flashes)
The controller status LED is the primary rear panel indicator of alarms. An alarm is
generated when a specific condition is identified and is cleared when the specified
condition is no longer detected. When an alarm is posted,
condition is no longer detected. When an alarm is posted,
1. The controller status LED turns orange for 5 seconds
2. The controller status LED turns off for 5 seconds
3. The controller status LED flashes orange the number of times specified by the first
digit of the alarm code
4. The controller status LED turns off for 3 seconds
5. The controller status LED flashes orange the number of times specified by the
second digit of the alarm code
Steps 2-5 are repeated for each alarm posted. The entire process is repeated as long as
the alarms are still posted.
the alarms are still posted.