Computime Limited RC713A ユーザーズマニュアル

ページ / 3
RC SERIES
REMOTE CONTROLS
INSTALLATION
OPERATION &
SERVICE MANUAL
SINGLE CHANNEL RADIO RECEIVERS
Model:  RC713L Switching Module / Model: RC715L Timer Override Module
For indoor and outdoor use, suitable for Pool/Spa equipment control
ELECTRICAL RATING: 15 Amp Resistive, 1200 Watt Tungsten, 1 HP Motor Load - 120 Volt.
FCC Information
NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one
or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Caution: Changes or modifications not expressly approved by Intermatic Inc. could void the user’s authority to operate this equipment.
These Modular Radio Receivers are one half of a two part remote control system.
They operate as ordinary ON/OFF switches but they also respond to the signals of
a hand held transmitter - the other half of the system. The modules are designed for
indoor or outdoor use, and can handle a variety of switching applications, typical
around the house or farm. By the push of a button on the face of the transmitter, the
user is able to turn ON/OFF the connected load (lights, pump, etc.) from any remote
location*, safely and conveniently. In addition, a single transmitter can operate up to
four Receivers and is able to “teach” each Module a different code. (Transmitters are
sold separately). 
Model RC713L Receiver Module comes with its own manual ON/OFF button and 
it is intended to be installed at the location of the load. The connected load may be
turned ON/OFF using the hand-held transmitter or turned ON/OFF by pushing the red
button on the face of the Receiver.
Model RC715L Receiver Module is the same as the RC713L Module above,
except it has no manual ON/OFF button on its face. This Module is designed to be
connected to a timer and will override its pre-set program, without affecting the next
automatic operation. At-site control of the load is possible by the ON/OFF switch of
the timer.
* The open field range is 100 feet but depends on many factors like the age of the battery, proximity of
large metal objects, the location of the receiver and environmental conditions at the time of transmission.
1
IMPORTANT SAFETY INSTRUCTIONS
1. This Control must be installed by a qualified electrician, according to National and Local Electrical Codes. 
2. USE COPPER CONDUCTORS ONLY. If applicable, install this Control not less than 5 feet (3 meters for Canadian 
installations) of inside edge of pool or spa.
3. Do not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors.
4. For grounding of the installation, refer to section 250 and 680 of the National Electrical Code.
5. This Control should not operate any equipment which would cause bodily injury or property damage should it be 
activated unexpectedly.
6. Always disconnect electricity at main panel before servicing this Control or the equipment(s) connected to it. 
THIS CONTROL IS NOT TO BE USED AS A POWER DISCONNECT.
READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL
GENERAL INFORMATION
Because of our commitment to continuing research and improvements, Intermatic Incorporated reserves the right to make changes, without notice, in the specifications and material 
contained herein and shall not be responsible for any damages, direct or consequential, caused by reliance on the material presented.
INTERMATIC INCORPORATED, SPRING GROVE, IL 60081
158RC10518
4
ONE YEAR LIMITED WARRANTY
If within the warranty period specified, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its
sole option, the unit free of charge. This warranty applies only to the original purchaser and is not transferable. This warranty does not apply to: (a) damage
caused by accident, abuse, mishandling, dropping, acts of God, or any negligent use; (b) units which have been subject to unauthorized repair, opened, taken
apart, or otherwise modified; (c) units not used in accordance with instructions (d) damages exceeding the cost of the product. Some stated do not allow a lim-
itation of damages, so the foregoing limitation may not apply to you. this warranty gives you specific legal rights and you may have other rights that vary from
state to state.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS
OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PAR-
TICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AT THE
WARRANTY PERIOD STATED ABOVE.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchase, or (b) mailing postage prepaid to the near-
est authorized service center listed. Please be sure to wrap the product securely when mailing to avoid shipping damage. This warranty is made by: Intermatic
Incorporated/After Sales Service, 7777 Winn Rd., Spring Grove, IL 60081-9698/8150675-7000 
http://www.intermatic.com
LIST OF AVAILABLE MODELS AND COMPONENTS
Model
Description
Specifications
RC713L
Single Channel Receiver
15 Amp Resistive, 10 Amp (1200 Watt) Tungsten,
3-way switching module
1 HP - 120 Volt, Single Pole Single Throw Contacts.
with 36 in. Lead
RC713R
Heavy-Duty Receiver
30 Amp Resistive - 120/240 Volt, 12.5 Amp (1500 Watt) 
and Relay Assembly
Tungsten - 120 Volt, 1.5 HP - 120 Volt, 3 HP - 240 Volt
Double Pole Single Throw Contacts.
RC715L
Single Channel Receiver
15 Amp Resistive, 10 Amp (1200 Watt) Tungsten
Timer Override Module
1 HP Motor Load - 120 Volt, Single Pole, Single Throw contacts.
with 36 in. Leads
RC949
4 Channel Transmitter
Operates on 9 Volt Battery
P1103ME
24 hr. Timer
Electronic Timer Mechanism -
Mechanism Only
replaces Intermatic T100 Series timers and compatible
with RC715L Receiver. Same rating as RC713R.
P1101R7
Portable Outdoor
15 Amp Resistive, 10 Amp (1200 Watt) Tungsten
Timer with Radio Override
1 HP Motor Load - 120 Volt.
TROUBLESHOOTING
Symptom
Possible Cause(s)
Corrective Action
No response to transmitter 
No power  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Turn ON power at main panel
signal at anytime
Loose connection(s) at receiver and/or load  . . . . . . . . . .Check connections
Transmitter battery dead  . . . . . . . . . . . . . . . . . . . . . . . . .Replace battery
Receiver and transmitter are on two different codes  . . . .Change code settings (see page 3)
Faulty transmitter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Check battery connections, replace transmitter
Faulty receiver  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Replace Receiver Module
No response to transmitter
Weak Battery  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Replace battery
signal some of the time
Appliance with brush type motor is in use  . . . . . . . . . . .Relocate appliance and/or connect to another circuit
Receiver is at edge of range . . . . . . . . . . . . . . . . . . . . . . .Mount Receiver closer or higher
Insufficient Range
Weak battery  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Replace battery
Antenna too close to ground  . . . . . . . . . . . . . . . . . . . . . .Relocate Receiver Module
Transmitter is held too close to ground  . . . . . . . . . . . . . .Hold transmitter at least 3 ft. above ground
Weak signal due to obstruction  . . . . . . . . . . . . . . . . . . . .Remote/relocate Receiver Module
Nuisance operation
Fluctuating supply voltage due to surge, etc.  . . . . . . . . .If frequent - install surge suppressor
Faulty receiver  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Replace receiver module