50D0098 RCSITE Installation & Operating Manual
Rel 0 Dec 2005
Rel 0 Dec 2005
Page 3 of 10
Ambient Technologies
A Division Of Monessen Hearth Systems
INSTALLATIONS
Remote Receiver:
The remote receiver may be installed in the appliance per the appliance homeowner’
s manual. Refer to the
Homeowner’
s Manual for special installation instructions. Failure to follow the installation instructions found
in the appropriate Homeowner’
s Manual will void the warranty and may cause a fire hazard.
This system comes with an 22 inch two-wire assembly labled “FOR MILLVOLT VALVE ONLY, TP/TH” and an
10 inch four-wire assembly labeled “SIT VALVE ONLY”. Insert the white terminals into the back of the receiver.
The terminal wire blocks can only be installed one way and do not force the terminal plugs into the receiver.
Connect the wiring terminal two (2) ¼” female spade terminals to the appliance valve and four-pin connector to SIT
valve. Refer to the appropriate Homeowner’
s Manual for proper wiring connections to the appliance. Your
appliance may have other options to connect wiring from receiver.
WARNING
STOP: Make sure SIT valve is correct. If not wired correctly, this could cause damage to
receiver.
Make sure that the wires do not contact the appliances any place other than at the terminals.
Exposure to temperatures higher than 105C (250º
receiver.
Make sure that the wires do not contact the appliances any place other than at the terminals.
Exposure to temperatures higher than 105C (250º
F) may cause the receiver to malfunction
and cause possible fire hazard.