RELM Communications Inc SRU50ABC ユーザーズマニュアル

ページ / 38
S Series Repeater USER MANUAL
©RELM Communications Inc.  Revision 1.0
11
Rear Panel Connectors
CONNECTOR
DESCRIPTION
DC POWER INPUT
13.8 Volt DC power input. Also +28 Volt input on spare pin.
SIMPLEX RELAY OUT OR
N TYPE RX INPUT
Location for internal simplex relay.  The antenna for RX / TX
connects to this point.  Else a N-Type connector can be used for the
input to the receiver for full duplex operation.
BNC RX INPUT
Standard BNC connector for the input to the receiver for full
duplex operation.
N TYPE TX OUTPUT
The RF power output from the transmitter for full duplex operation.
SPARE RJ11
Provision for internal expansion.
DB25-F PARALLEL I/O
Provides two 8 bit input ports, where one is used as the parallel
BCD channel select.  Also one spare 8 bit input port.
DB15 UNIVERSAL
ANALOG I/O
Provides the necessary analog receiver and transmitter interface for
system expansion.
RS-232 SERIAL PORT
9600 Baud serial port for frequency programming, channel
selection and alarm and status monitoring.
SPARE DB15
Provision for internal expansion.
Rear view SR35/50
DC POWER INPUT
             SIMPLEX RELAY OUT
             OR N TYPE RX INPUT OR BNC RXINPUT
         N TYPE TX OUTPUT
THERMALLY CONTROLLED FAN
SPARE
  RJ11
TRANSMITTER HEATSINK
 HOLE
      
 
SPARE
4 OFF SCREWS FOR
       DB25-F
DB15
EASY PA MODULE
PARALLEL I/O
        
HOLE
REMOVAL
DB15 UNIVERSAL 
RS-232
ANALOG I/O
   
SERIAL PORT