VeriFone 1619-20XPL ユーザーズマニュアル
CONFIDENTIAL
Version A
Page 21 of 37
MasterCard® PayPass™ Contactless Transit Pilots
Installation Guide
3.4.2
Run the Interconnect Cable
The Interconnect cable joins the Secura Control Unit Assembly and the Contactless
Reader Assembly.
Reader Assembly.
1.
Cut a sufficient length of 12-way multi-core cable to allow it to be comfortably run
between the sites of the Secura Control Unit Assembly and the contactless card
reader assembly. Note that the maximum length of cable connecting the Secura and
the Contactless Reader shall be no more than 15 feet.
between the sites of the Secura Control Unit Assembly and the contactless card
reader assembly. Note that the maximum length of cable connecting the Secura and
the Contactless Reader shall be no more than 15 feet.
2.
Ensure that the cable is not twisted or pinched anywhere along its length
3.
Strip 12cm (4.7in) of the cable sheath at both ends, to facilitate connection to the
Secura and Contactless Reader respectively.
Secura and Contactless Reader respectively.