VeriFone 1619-20XPL ユーザーズマニュアル

ページ / 37
 
 
CONFIDENTIAL 
Version A 
Page 26 of 37 
MasterCard® PayPass™ Contactless Transit Pilots 
Installation Guide 
 
 
3.4.4
 
Install the Contactless Card Reader Assembly 
The fixing points / metal tubing will be pre-installed. 
1.
 
Remove the clamps 
2.
 
Remove the 4 screws from the base of the unit 
3.
 
Prise the bottom away from the tube, revealing the connectors 
4.
 
Feed the 12-way cable through the grommet on the base of the assembly. 
5.
 
Connect  the  12-way  multi-core  to  the  Card  Reader  Assembly,  using  the  following 
diagram as a guide. 
7
Brown
8
Yellow
9
Red
10
Green
11
Black
12
Orange
3
Yellow
4
Green
5
Black
6
Red
Card reader
1
Brown
2
Black
Speaker
Card reader
LED indicators
Operator LED
From LED Board
LED
Cut Back Tail of 12cm on the 12
way multi core cable - remove
the earth brade
1
2
 w
a
y
 c
a
b
le
 
6.
 
You will need to measure the voltage between pins 3 and 5, i.e. power and ground. 
The  voltage  must  NOT  be  below  +7.5V.  Measure  on  the  card  reader  side.  If  the 
voltage is below +7.5V, you will need to reduce the cable length. There is a drop of 
0.08V per metre of cable. 
7.
 
Have  a  colleague  double-check  the  multi-core  connections.  Please  note  that  it  is 
absolutely essential that the connections are secured properly and the wiring diagram 
is  correctly  followed.  Incorrect  connection  will  possibly  blow  the  LEDs  in  the 
contactless card reader assembly. 
8.
 
Re-attach  the  clamps  and  the  four  hex  screws,  ensuring  to  lightly  grease  the  hex 
bolts  which  are  used  to  secure  the  clamp  on  the  handrail,  in  order  to  prevent 
corrosion and to facilitate later removal if required.