VeriFone 1619-20XPL ユーザーズマニュアル
CONFIDENTIAL
Version A
Page 26 of 37
MasterCard® PayPass™ Contactless Transit Pilots
Installation Guide
3.4.4
Install the Contactless Card Reader Assembly
The fixing points / metal tubing will be pre-installed.
1.
Remove the clamps
2.
Remove the 4 screws from the base of the unit
3.
Prise the bottom away from the tube, revealing the connectors
4.
Feed the 12-way cable through the grommet on the base of the assembly.
5.
Connect the 12-way multi-core to the Card Reader Assembly, using the following
diagram as a guide.
diagram as a guide.
7
Brown
8
Yellow
9
Red
10
Green
11
Black
12
Orange
3
Yellow
4
Green
5
Black
6
Red
Card reader
1
Brown
2
Black
Speaker
Card reader
LED indicators
Operator LED
From LED Board
LED
Cut Back Tail of 12cm on the 12
way multi core cable - remove
the earth brade
1
2
w
a
y
c
a
b
le
6.
You will need to measure the voltage between pins 3 and 5, i.e. power and ground.
The voltage must NOT be below +7.5V. Measure on the card reader side. If the
voltage is below +7.5V, you will need to reduce the cable length. There is a drop of
0.08V per metre of cable.
The voltage must NOT be below +7.5V. Measure on the card reader side. If the
voltage is below +7.5V, you will need to reduce the cable length. There is a drop of
0.08V per metre of cable.
7.
Have a colleague double-check the multi-core connections. Please note that it is
absolutely essential that the connections are secured properly and the wiring diagram
is correctly followed. Incorrect connection will possibly blow the LEDs in the
contactless card reader assembly.
absolutely essential that the connections are secured properly and the wiring diagram
is correctly followed. Incorrect connection will possibly blow the LEDs in the
contactless card reader assembly.
8.
Re-attach the clamps and the four hex screws, ensuring to lightly grease the hex
bolts which are used to secure the clamp on the handrail, in order to prevent
corrosion and to facilitate later removal if required.
bolts which are used to secure the clamp on the handrail, in order to prevent
corrosion and to facilitate later removal if required.