MasterCard® PayPass™ Contactless Transit Pilots 
Installation Guide 
 
3.4.5
 
Functional Test 
1.
 
Have the bus apply power to the solution. Ensure that the Secura powers up correctly 
and  the  LEDS  light  up  on  the  contactless  card  reader  assembly.  The  Secura  display 
will display a couple of events, namely: 
o
 
Event 20 – power up 
o
 
Event 23 – In Service 
2.
 
A  number  of  self-tests  can  then  be  carried  out  using  the  keyboard  functions  of  the 
Secura. Refer to section 5 for full details of the available functions. 
a)
 
Select function 37 on the keyboard, press 3, 7 then ENT. This will switch on 
the green LEDs 
b)
 
Select function 38 on the keyboard, press 3, 8 then ENT. This will switch on 
the green LEDs 
c)
 
Select  function  26  on  the  keyboard,  press  2,  6  then  ENT.  This  will  exercise 
the green LEDs, the red LEDS and fire a turnstile release (solenoid) pulse. 
d)
 
If  the  terminal  has  not  contacted  MMS  when  power  was  applied,  perform  a 
communications test to ensure that connectivity with MMS can be established 
satisfactorily. Do this by selecting function 46. 
e)
 
Test  that  communications  with  the  Transit  Payment  Platform  Authorisation 
Server can be established by performing function 44. 
f)
 
Test  that  communications  with  the  Transit  Payment  Platform  Batch  Server 
can be established by performing function 45. 
g)
 
Ensure  that  the  terminal  is  taken  out  of  diagnostic  mode  by  performing 
function 10. 
h)
 
Other  available  test  functions  can  be  performed  –  refer  to  section  5  for  full 
details of the available functions. 
3.4.6
 
Fit Cover 
1.
 
Once the functional tests have passed successfully, fit the outer cover to the solution 
as shown: 
 
2.
 
Sign the bus back over to the transit agency