VeriFone VX600BTCTLS ユーザーズマニュアル

ページ / 31
D
EVICE
 S
ETUP
 
Installing the Battery
16
VX 600 B
LUETOOTH
 A
GNOSTIC
 I
NSTALLATION
 G
UIDE
To remove the battery
Hook your finger under the latch and lift up to remove the battery.
Charging the 
Battery 
Provided that the VX 600 Bluetooth Agnostic is turned on, you can still use the 
device to process transactions. Although, certain device functions are disabled, 
depending on the charge capacity of the battery. For more information, see 
 below.
To charge the battery
1
Pull out the cover and insert the micro-USB cable into the port located on the 
right side of the VX 600 Bluetooth Agnostic.
2
Connect the other end of the micro-USB cable into a USB wall mount charger 
and plug into a outlet or powered surge protector.
Figure 9
Charging the battery
Table 3
Battery Discharge Mode
Battery States
System Protections
Voltage
(Fuel Gauge)
Capacity
Battery Pack
Operating System
4.2 V
100%
Normal 
Discharge
3.0 V
0%
Over-discharge protection:
battery circuit cut-off power 
if V<2.3V
1
Low battery protection:
 
- stop CTLS operation if V<3.7V
 
- stop Bar Code operation if V<3.6V
2
Over-discharge protection:
 
power off system if V <3.3V
3
Over-discharge temperature 
protection:
 
power off system if T<=-15C or 
T>=60C
Over discharge 
cut off
2.3 V
N/A
N/A
0V
N/A