Setting the Unit Number
2.
Insert the magnet into the nibs on the module cover. 
Remove the magnet clip from the module back-plate 
and press the magnet clip down over the magnet until it 
clicks into place (Figure 7).
3.
Connect the normally closed reed switch (in series with 
a 2.0K ohm EOL resistor) to the desired panel, HIM, or 
SnapCard zone input terminals. The resistor should be 
located at the reed switch inside the module housing.
Figure 7. Installing the Optional Reed Switch
Setting the Unit Number
Each bus module connected to the panel must have a differ-
ent unit number set for correct communication.
Setting the Unit Number on Concord Panels with 
Software Versions 1.0–1.6
The module can be set to any unit number 0–15, using the 
module DIP switches.
Note
Do not set the SuperBus 2000 RF Receiver unit num-
ber to 15 if it is installed in a Concord RF system, 
since the built-in receiver is factory set to unit number 
15 and cannot be changed.
Locate the DIP switches on the module and set them to the 
desired unit number (0–15) before applying power (see Fig-
ure 8)
.
Figure 8. Unit Number DIP Switch Settings
Setting the Unit Number on Concord Panels with 
Software Version 2.0 or Later
The unit number will be automatically set when powering 
up the system. No action is required by the installer.
Power Up and Bus Communication
Use the following procedures for powering up the system 
and verifying bus communication.
Note
In order to enter panel program mode to verify unit 
numbers, an alphanumeric touchpad must be con-
nected to all Concord panels.
To power up the panel and receiver module:
1.
Verify that all wiring at the panel, touchpad, and 
receiver is correct.
2.
Connect the panel backup battery and plug in the panel 
AC power transformer.
3.
Verify that the receiver module status LED is on.
4.
If desired, enter panel program mode to verify unit 
number exists (see panel Installation Instructions for 
more information).
Note
If the receiver module LED is not on, unplug the panel 
AC power transformer, disconnect the backup battery, 
and see Table 3 “Troubleshooting”.
9712G12A.DSF
MODULE
BACK-PLATE
MODULE
COVER
REED
SWITCH
MAGNET
CLIP
MAGNET
TO ANY ZONE
INPUT
2.0K OHM EOL
RESISTOR (49-467)
1065G05A.DSF
UNIT NUMBER 0
1 2 3 4
ON
UNIT NUMBER 1
1 2 3 4
ON
UNIT NUMBER 2
1 2 3 4
ON
UNIT NUMBER 3
1 2 3 4
ON
UNIT NUMBER 4
1 2 3 4
ON
UNIT NUMBER 5
1 2 3 4
ON
UNIT NUMBER 6
1 2 3 4
ON
UNIT NUMBER 7
1 2 3 4
ON
UNIT NUMBER 8
1 2 3 4
ON
UNIT NUMBER 9
1 2 3 4
ON
UNIT NUMBER 10
1 2 3 4
ON
UNIT NUMBER 11
1 2 3 4
ON
UNIT NUMBER 12
1 2 3 4
ON
UNIT NUMBER 13
1 2 3 4
ON
UNIT NUMBER 14
1 2 3 4
ON
UNIT NUMBER 15--Do not use in Concord RF systems.