Gait Up PHYS5POMOC ユーザーズマニュアル

ページ / 15
 
12 June 2017 - Physilog5usermanual.pdf-v1.2.3 - Check www.gaitup.com for the latest version. Copyright 􂡥2017 Gait Up SA. CH-1015 SWITZERLAND               
11
 
 5.6  Battery autonomy estimations 
Measuring channels
 
Radio settings 
Firmware 
version 
Approx. 
Autonomy * 
3D 
Accelerometer 
3D Gyroscope 
 Barometric 
pressure 
Master / slave / 
no radio 
Version 
(release date) 
Hours 
256Hz 
256Hz 
64Hz 
1.0.2 
(02.03.2017) 
18h 
128Hz 
128Hz 
64Hz 
Master / slave 
pairs / no radio
 
1.1.0 
(14.06.2017)
 
20h
 
128Hz 
128Hz 
64Hz 
Slave without 
master
 
1.1.0 
(14.06.2017)
 
10h
 
256Hz 
256Hz 
64Hz 
Master / slave 
pairs / no radio
 
1.1.0 
(14.06.2017)
 
18h
 
256Hz 
256Hz 
64Hz 
Slave without 
master
 
1.1.0 
(14.06.2017)
 
10h
 
512Hz 
512Hz 
64Hz 
Master / slave 
pairs / no radio
 
1.1.0 
(14.06.2017)
 
15h 
512Hz 
512Hz 
64Hz 
Slave without 
master
 
1.1.0 
(14.06.2017)
 
10h 
*Autonomy measured at room temperature 
 
 5.7  Troubleshoot 
Soft reset 
The soft reset is the manipulation which can be done if the Physilog® is not working properly.  
To do a soft reset, hold the main button for 15 seconds. The LED shines red/orange and then 
stops.  If  the  problem  persists,  fill  out  the  contact  form  on  the  support  page 
(
)  or  write  an  email  to:  contact@gaitup.com.  Please  indicate 
Physilog® serial number and describe the problem in as much detail as possible (number of 
red blinks, last manipulation etc.).