SOYAL TECHNOLOGY CO. LTD. AR-837 ユーザーズマニュアル
V140217
LCD / Biometrics Access Controller
E. PIN Code
Access programming mode →
User Setting → Password → Input 5-digit user address → Input 4-digit PIN (0001~9999) → Succeeded
Or via 701Client set it on Users screen
2
1
C. Initial setup
Node ID of Reader Setting
Access programming mode → Parameters[1] → Node ID →
Access programming mode → Parameters[1] → Node ID →
Input New Node ID : 1~254 (default value:001) → Main Door Number : 0~255
→
WG1 Door Number : 0~255 → Show UID (0=No, 1=WG, 2=ABA, 3=HEX) → Enable DHCP(0:No, 1:En, 2=Exit) → Succeeded
3
1
Language Setting
Access programming mode → Tools → Language → EN → Succeeded → Initial system...
Access programming mode → Tools → Language → EN → Succeeded → Initial system...
5
1
0
Programming
B. Entering and Exiting Programming Mode
Exiting
Press the repeatedly → Quit or Quit and Arming (Please refer to alarm / arming setting)
Press the repeatedly → Quit or Quit and Arming (Please refer to alarm / arming setting)
6
Changing the Master Code
Access programming mode → Tools → Master Code → Input the 6-digit new master code → Succeeded
Access programming mode → Tools → Master Code → Input the 6-digit new master code → Succeeded
5
2
A. Keyboard Lock/ Unlock
Lock/ Unlock
Press and simultaneously to lock keyboard. Press simultaneously again to unlock.
Entering
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456. If already changed the Master Code= 876112, input 876112 → Access programming mode
P.S.If no instruction is entered within
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456. If already changed the Master Code= 876112, input 876112 → Access programming mode
P.S.If no instruction is entered within
30 sec., it will automatically leave the programming mode.
7
Access programming mode → Add/Delete → Add -> RF-Learn →
Input 5-digit user address
→
Input Tag Units(pcs) → Close Tag into RF Area
※
If the batch of tags are
Sequential, input Tag Units(pcs) in the quantity of the tags and present the tag with
the
lowest number to the controller for adding all the tag data; otherwise, the tags must be presented to the controller individually
1
2
Adding Tag by RF Learn Function
Tag Information
SITE CODE
CARD CODE
SITE CODE
CARD CODE
※
User capacity: 16384 (00000~16383)
Access programming mode → Add/Delete → Add -> Card ID →
Input 5-digit user address → Input Site Code → Input Card Code
1
1
Adding Tag by Tag ID
Access programming mode → Add/Delete → Delete -> Addr →
Input Start address → Input End address
1
5
Deleting User Address
Access programming mode → User Setting → Access Mode →
Input User Address → 0: Invalid; 1: Card ; 2: Card or PIN; 3: Card & PIN
2
2
Setting up the access mode
Access programming mode → Add/Delete → Delete -> ID # →
Input Site Code → Input Card Code
1
6
Deleting Tag by Tag ID
Access programming mode → Add/Delete → Suspend -> Addr →
Input Start address → Input End address
1
3
Suspend User Address
Access programming mode → Add/Delete → Suspend -> ID # →
Input Site Code → Input Card Code
1
4
Suspend Tag by Tag ID
Access programming mode → Add/Delete → Delete -> Addr →
Input Start address → Input End address
1
7
Recover User Address
Access programming mode → Add/Delete → Delete -> ID # →
Input Site Code → Input Card Code
1
8
Recover Tag by Tag ID
D. Adding and Deleting Tag