H. Arming Password
J. Duress Code
K. Terminal Port
I. Arming Delay Time
Access programming mode →
Parameters[1] → Arming PWD → Input 4-digit PIN (0001~9999; Default: 1234) → Succeeded
Or via 701Server and set it on AR-829E screen
3
8
Or via 701Server to set it on AR-829E-V5 screen
※
※
Duress Code is only available in networking mode. It will substitute a personal pin code and send the message of Duress to computer as a
warning signal.
Access programming mode →
Parameters[2] → Duress Code → 4 sets (select one) → Input 4-digit PIN (0001~9999) → Succeeded
4
7
Access programming mode →
Tools → Terminal Port → 0:Lift ; 1:Host ; 2:LED ; 3:PRN (default value:1) → Baud Selection
(default value:9600) → Succeeded
5
4
L. Setting up the alarm / arming
Conditions:
1. Arming enabled
2.Alarm system connected
1. Arming enabled
2.Alarm system connected
Situations:
1. Door is open overtime: Door is open longer than door relay time plus door close time.
2. Force open (Opened without a valid user card): Access by force or illegal procedure.
3. Door position is abnormal: Happening when power is off and then on again, besides, reader was on arming before power went off.
1. Door is open overtime: Door is open longer than door relay time plus door close time.
2. Force open (Opened without a valid user card): Access by force or illegal procedure.
3. Door position is abnormal: Happening when power is off and then on again, besides, reader was on arming before power went off.
Enable/Disable the arming status:
Standby Mode
Access Programming mode
Card only
Card or PIN
Card and PIN
Open the door
Present the tag to reader →
Present the tag to reader →
Input
4-digit arming PWD →
Input user address → Input
4-digit individual PWD → →
Input 4-digit arming PWD →
4-digit individual PWD → →
Input 4-digit arming PWD →
Present the tag to reader →
Input
4-digit individual PWD → →
Input 4-digit arming PWD →
Input 4-digit arming PWD →
Enable: Access programming mode → Quit & Arming
7
Disable: Access programming mode → Quit
6
No open the door
→
→
Input 4-digit arming PWD
→
Present the tag to reader
Access programming mode → Parameters[1] → ArmingDelayTm →
Enter armed sta. Delay time(Sec), Range:000~255;
Armed pulse out-put time (10ms) ,Range:000~255 → Succeeded
3
7
※
[Use FP] can substitute for [Induct valid card].
F. Adding / Deleting Fingerprint
Adding
Access programming mode →
Access programming mode →
User Setting → Enroll FP → Key in 5-digit user address →1 or 2 different fingers on the sensor lens → Succeeded
P.S. The AR-837EF needs to collect twice for each fingerprint.
2
6
Deleting
Access programming mode →
Access programming mode →
User Setting → Delete FP → Key in 5-digit user address → Succeeded
P.S. If you want to delete all users’ FP, key in
99999
2
7
#
G. Access Mode
Access programming mode →
User Setting
→
Access Mode
→
Key in 5-digit user address (00000~08999)
→
0: Invalid; 1:Card; 2: Card or PIN; 3: Card and PIN
(
837EF: → Finger Identify: 0: Must ; 1: Ignore )
→
Succeeded
2
2
Access Mode
Finger Identify (837EF Only)
Result (837EF Only)
Hardware 701Client
Hardware
701Client
0:Invalid
0: Must
Just fingerprint
Just card control
Invalid User
1: Ignore
Just fingerprint
Just card control
1:Card
0: Must
Just fingerprint
Just card control
Finger+Card
1: Ignore
Just fingerprint
Just card control
1. Card Only
2. Finger Only
2:Card or PIN
0: Must
Just fingerprint
Just card control
1. Finger+Card
2. Finger+PIN
3. Card+Finger+PIN
4. Card+Finger+Card
5. PIN+Finger+PIN
6. PIN+Finger+Card
1: Ignore
Just fingerprint
Just card control
1. Card Only
2. PIN Only
3. Finger Only
3:Card and PIN
0: Must
Just fingerprint
Just card control
Finger+Card+PIN
1: Ignore
Just fingerprint
Just card control
1. Card+PIN
2. Finger+PIN