8.1 AT
Use to test if connection of module is OK. This is a dummy command just like other common "AT
modules"
Format:
AT
AT?
Return:
+AT: OK
8.2 ID
Use to check the ID of the LoRaWAN module, or change the ID.
Read ID Format:
AT+ID
// Read all, DevAddr(ABP), DevEui(OTAA), AppEui(OTAA)
AT+ID?
// Read all
AT+ID=?
// Read all
AT+ID=DevAddr
// Read DevAddr
AT+ID=DevEui
// Read DevEui
AT+ID=AppEui
// Read AppEui
AT+ID=DevAddr, "new devaddr"
// Set new DevAddr
AT+ID=DevEui, "new deveui"
// Set new DevEui
AT+ID=AppEui, "new appeui"
// Set new AppEui
Return:
+ID: DevAddr, xx:xx:xx:xx
+ID: DevEui
, xx:xx:xx:xx:xx:xx:xx:xx
+ID: AppEui
, xx:xx:xx:xx:xx:xx:xx:xx
Change end device address (
DEVADDR)
AT+ID=DevAddr, “4 bytes length hex identifier”
eg: AT+ID=DevAddr, "01234567"
eg: AT+ID=DEVADDR, "01 23 45 67"
Return:
+ID: DevAddr, 01:23:45:67
Change device extended unique identifier (
DEVEUI)
AT+ID= DevEui, “8 bytes length hex identifier (64bit)”
eg: AT+ID=DevEui, "0123456789ABCDEF"
eg: AT+ID=DEVEUI, "01 23 45 67 89 AB CD EF"
Return:
+ID: DevEui, 01:23:45:67:89:AB:CD:EF
Change device extended unique identifier (
APPEUI)
4
DevEui which is supplied by RisingHF are derived from STM32's UUID, these EUIs are RisingHF unique is not standard
IEEE EUI-64, , it is recommended to apply and use IEEE-EUI64.
5
Default AppEui is
52:69:73:69:6E:67:48:46