Intel S2400GP4 DBS2400GP4 ユーザーズマニュアル

製品コード
DBS2400GP4
ページ / 156
Intel
®
 Light Guided Diagnostics 
Intel
®
 Server Board S2400GP TPS
 
 
 
Revision 1.01 
Intel order number G50295-002 
112 
The bi-color (green/amber) System Status LED operates as follows: 
Table 46. System Status LED 
Color 
State 
Criticality 
Description 
Off
 
System is 
not 
operating
 
Not ready
 
1.  System is powered off (AC and/or DC). 
2.  System is in EuP Lot6 Off Mode. 
3.  System is in S5 Soft-Off State. 
4.  System is in S4 Hibernate Sleep State. 
Green
 
Solid on
 
Ok
 
Indicates that the System is running (in S0 State) and its status is 
‘Healthy’. The system is not exhibiting any errors. AC power is 
present and BMC has booted and manageability functionality is up 
and running. 
Green
 
~1 Hz blink
 
Degraded - 
system is 
operating in a 
degraded state 
although still 
functional, or 
system is 
operating in
 
a redundant state 
but with an 
impending failure 
warning
 
 
System degraded: 
  Redundancy loss, such as power-supply or fan. Applies only if the 
associated platform sub-system has redundancy capabilities. 
  Fan warning or failure when the number of fully operational fans is 
more than minimum number needed to cool the system. 
  Non-critical threshold crossed 
– Temperature (including HSBP 
temp), voltage, input power to power supply, output current for 
main power rail from power supply and Processor Thermal 
Control (Therm Ctrl) sensors. 
  Power supply predictive failure occurred while redundant power 
supply configuration was present. 
  Unable to use all of the installed memory (one or more DIMMs 
failed/disabled but functional memory remains available) 
  Correctable Errors over a threshold and migrating to a spare 
DIMM (memory sparing). This indicates that the user no longer 
has spared DIMMs indicating a redundancy lost condition. 
Corresponding DIMM LED lit. 
  Uncorrectable memory error has occurred in memory Mirroring 
Mode, causing Loss of Redundancy. 
  Correctable memory error threshold has been reached for a failing 
DDR3 DIMM when the system is operating in fully redundant RAS 
Mirroring Mode. 
  Battery failure. 
  BMC executing in uBoot. (Indicated by Chassis ID blinking at 
Blinking at 3Hz). System in degraded state (no manageability). 
BMC uBoot is running but has not transferred control to BMC 
Linux*. Server will be in this state 6-8 seconds after BMC reset 
while it pulls the Linux* image into flash. 
  BMC booting Linux*. (Indicated by Chassis ID solid ON). System 
in degraded state (no manageability). Control has been passed 
from BMC uBoot to BMC Linux* itself. It will be in this state for 
~10-~20 seconds. 
  BMC Watchdog has reset the BMC. 
  Power Unit sensor offset for configuration error is asserted. 
  HDD HSC is off-line or degraded. 
Amber
 
~1 Hz blink
 
Non-critical - 
System is 
operating in a 
degraded state
 
with an impending 
failure warning,
 
although still 
functioning
 
Non-fatal alarm 
– system is likely to fail: 
  Critical threshold crossed 
– Voltage, temperature (including HSBP 
temp), input power to power supply, output current for main power 
rail from power supply and PROCHOT (Therm Ctrl) sensors. 
  VRD Hot asserted. 
  Minimum number of fans to cool the system not present or failed 
  Hard drive fault