HP P4300 G2 16TB MDL SAS BK715B ユーザーズマニュアル

製品コード
BK715B
ページ / 39
 
P4300 G2
MDL SAS
Starter SAN
P4300 G2 SAS
Starter SAN
P4500 G2
Virtualization
SAN
P4500 G2
Multi-Site
SAN
P4500 G2
Scalable
Capacity SAN
P4900 G2
6.4TB SSD
Storage
System
P4800 G2 SAN
for
BladeSystem
*
Dimensions
4U
8U
10U
4U
15U
6.9 x 17.64 x 28.23 in
(17.52 x 44.80 x 71.71 cm)
13.8 x 17.64 x
28.23 in
(35.04 x 44.80
x 71.71 cm)
17.25 x 17.64
x 28.23 in
(43.8 x 44.80
x 71.71 cm)
6.9 x 17.64 x
28.23 in(17.52
x 44.80 x
71.71 cm)
26.25 x 17.64
x 35.08 in
(66.68 x 44.80
x 89.12 cm)
Weight
76 lbs/34.46 kg
90 lbs/40.82
kg
180 lbs/
81.64 kg
225 lbs/
102.05 kg
75 lbs/34.01
kg
572.3 lbs/
259.59 kg
Power/Cooling
Redundant Hot-Plug Common Slot Power Supplies
(
*DC also supported in P4300 G2 & P4500 G2
)
Dependent
upon final
C7000
Enclosure
Config.
Auto-switching universal 115/220 Volts
5.3 belsA-weighted
@115V 1418 BTU/hr 1760 BTU/hr
2248 BTU/hr 4996 BTU/hr
4205 BTU/hr
1594 BTU/hr
416 watts
524 watts
658 watts
1316 watts
1230 watts
466 watts
@220V 1394 BTU/hr 1788 BTU/hr
2214 BTU/hr 4428 BTU/hr
4130 BTU/hr
1568 BTU/hr
408 watts
516 watts
648 watts
1296 watts
1210 watts
458 watts
Environmental
System Inlet Temperature Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude Derating of 1.0°C per every 305 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3050 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the
type and number of options installed. System
performance may be reduced if operating with a
fan fault or above 30°C (86°F).
Non-operating
-30°to 60°C (-22°to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity (non-
condensing)
Operating 10% to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet
bulb temperature, non-condensing.
Non-operating 5% to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum
wet bulb temperature, non-condensing.
Altitude
Operating 3050 m (10,000 ft). This value may be limited by the type and
number of options installed. Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating 9144 m (30,000 ft). Maximum allowable altitude change rate is
457 m/min (1500 ft/min).
Regulatory
EMC: Class A:
CISPR 22:2005, EN 55022:2006, EN 55024:1998 +A1:2001 +A2:2003, EN 61000-3-2:2006, EN 61000-3-
3:1995 +A1:2001 +A2:2005
Safety: EN 60950-1:2001
* BladeSystem SAN numbers based on configuration within a C7000 BladeSystem Enclosure.
QuickSpecs
HP P4000 G2 LeftHand SAN Solutions
Technical Specifications
DA - 13552   North America — Version 23 — October 19, 2012