HP P4300 G2 16TB MDL SAS BK715B 사용자 설명서

제품 코드
BK715B
다운로드
페이지 39
 
P4300 G2
MDL SAS
Starter SAN
P4300 G2 SAS
Starter SAN
P4500 G2
Virtualization
SAN
P4500 G2
Multi-Site
SAN
P4500 G2
Scalable
Capacity SAN
P4900 G2
6.4TB SSD
Storage
System
P4800 G2 SAN
for
BladeSystem
*
Dimensions
4U
8U
10U
4U
15U
6.9 x 17.64 x 28.23 in
(17.52 x 44.80 x 71.71 cm)
13.8 x 17.64 x
28.23 in
(35.04 x 44.80
x 71.71 cm)
17.25 x 17.64
x 28.23 in
(43.8 x 44.80
x 71.71 cm)
6.9 x 17.64 x
28.23 in(17.52
x 44.80 x
71.71 cm)
26.25 x 17.64
x 35.08 in
(66.68 x 44.80
x 89.12 cm)
Weight
76 lbs/34.46 kg
90 lbs/40.82
kg
180 lbs/
81.64 kg
225 lbs/
102.05 kg
75 lbs/34.01
kg
572.3 lbs/
259.59 kg
Power/Cooling
Redundant Hot-Plug Common Slot Power Supplies
(
*DC also supported in P4300 G2 & P4500 G2
)
Dependent
upon final
C7000
Enclosure
Config.
Auto-switching universal 115/220 Volts
5.3 belsA-weighted
@115V 1418 BTU/hr 1760 BTU/hr
2248 BTU/hr 4996 BTU/hr
4205 BTU/hr
1594 BTU/hr
416 watts
524 watts
658 watts
1316 watts
1230 watts
466 watts
@220V 1394 BTU/hr 1788 BTU/hr
2214 BTU/hr 4428 BTU/hr
4130 BTU/hr
1568 BTU/hr
408 watts
516 watts
648 watts
1296 watts
1210 watts
458 watts
Environmental
System Inlet Temperature Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude Derating of 1.0°C per every 305 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3050 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the
type and number of options installed. System
performance may be reduced if operating with a
fan fault or above 30°C (86°F).
Non-operating
-30°to 60°C (-22°to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity (non-
condensing)
Operating 10% to 90% relative humidity (Rh), 28°C (82.4°F) maximum wet
bulb temperature, non-condensing.
Non-operating 5% to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum
wet bulb temperature, non-condensing.
Altitude
Operating 3050 m (10,000 ft). This value may be limited by the type and
number of options installed. Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating 9144 m (30,000 ft). Maximum allowable altitude change rate is
457 m/min (1500 ft/min).
Regulatory
EMC: Class A:
CISPR 22:2005, EN 55022:2006, EN 55024:1998 +A1:2001 +A2:2003, EN 61000-3-2:2006, EN 61000-3-
3:1995 +A1:2001 +A2:2005
Safety: EN 60950-1:2001
* BladeSystem SAN numbers based on configuration within a C7000 BladeSystem Enclosure.
QuickSpecs
HP P4000 G2 LeftHand SAN Solutions
Technical Specifications
DA - 13552   North America — Version 23 — October 19, 2012