Superior Essex 09-097-02 ユーザーズマニュアル
B-11
Toll Free 800.551.8948 | Fax 770.657.6807 |
Rev 11/10 Ed 10.4
Dry Block/Sunlight Resistant Indoor/Outdoor
OFNR
Specifications
2-12 Fiber
Single Unit Design
Configuration
Flexible tight buffer material extruded over fiber to 900 μm
diameter; color coded fibers are combined with dielectic
aramid yarns for strength and water blocking
18-36 Fiber
Multi-Unit Design
Configuration
Dry water-blocked 6-fiber sub-units are grouped to form cable
core; core consits of sub-units cabled with additional
strength members and water blocking elements
48-144 Fiber
Multi-Unit Design
Configuration
Dry water-blocked 12-fiber sub-units are grouped to form
cable core; core consists of sub-units cabled with
additional strength members and water blocking elements
Jacket
Black, flame retardant, chemical and sunlight resistant PVC
Performance
Compliance
UL 1651
CSA C22.2 No. 232
UL 1666
Telcordia gR-20-CORE, Issue 3
ANSI/ICEA S-104-696-2001
ANSI/TIA-568-C.3
RoHS-compliant
NRTL Programs
UL, c(UL) Listed OFNR
UL, c(UL) Listed Sunlight Resistant
Environmental Specifications
Operation
-40°C to +75°C
Storage/Shipping
-40°C to +75°C
Installation
-20°C to +65°C
Part Numbers and Physical Characteristics
Part Number¹
Fiber Count
Nominal
Diameter
in (mm)
Nominal Weight
lbs/kft (kg/km)
Maximum Tensile Loading
Minimum Bend Radius
Install
lbs (N)
Long Term
lbs (N)
Install
in (mm)
Long Term
in (mm)
W3002xx01
2
0.20 (5.0)
14 (21)
300 (1,340)
90 (400)
3.0 (75)
2.0 (50)
W3004xx01
4
0.20 (5.0)
15 (23)
300 (1,340)
90 (400)
3.0 (75)
2.0 (50)
W3006xx01
6
0.20 (5.0)
16 (23)
300 (1,340)
90 (400)
3.0 (75)
2.0 (50)
W3008xx01
8
0.24 (6.0)
21 (31)
300 (1,340)
90 (400)
3.5 (90)
2.4 (60)
W3012xx01
12
0.26 (6.5)
25 (38)
300 (1,340)
90 (400)
3.8 (97)
2.6 (65)
W3018xx01
18
0.55 (14.1)
100 (149)
600 (2,700)
180 (800)
8.3 (211)
5.5 (141)
W3024xx01
24
0.59 (14.9)
122 (182)
600 (2,700)
180 (800)
8.8 (224)
5.9 (149)
W3030xx01
30
0.63 (16.1)
147 (220)
600 (2,700)
180 (800)
9.5 (242)
6.3 (161)
W3036xx01
36
0.70 (17.7)
179 (267)
600 (2,700)
180 (800)
10.5 (266)
7.0 (177)
W3048xx01
48
0.70 (17.8)
161 (241)
600 (2,700)
180 (800)
10.5 (267)
7.0 (178)
W3060xx01
60
0.78 (19.8)
204 (304)
600 (2,700)
180 (800)
11.7 (297)
7.8 (198)
W3072xx01
72
0.84 (21.3)
243 (362)
600 (2,700)
180 (800)
12.6 (320)
8.4 (213)
W3084xx01
84
0.91 (23.2)
294 (439)
600 (2,700)
180 (800)
13.7 (347)
9.1 (232)
W3096xx01
96
0.98 (25.0)
345 (515)
600 (2,700)
180 (800)
14.8 (375)
9.8 (250)
W3144xx01
144
1.11 (28.3)
375 (559)
600 (2,700)
180 (800)
16.7 (425)
11.1 (283)
Single Mode Optical Fiber
Multimode Optical Fiber
Reduced
Water Peak
Zero
Water Peak
TeraFlex
®
Bend Resistant
Teragain
®
62.5/125
Teragain Laser Optimized 50/125
TeraFlex Bend Resistant
Laser Optimized 50/125
10g/150
10g/300
10g/550
10g/150
10g/300
10g/550
¹Replace “xx” with:
31
21
K1
¹Replace “xx” with:
6g
Ag
Bg
Fg
Mg
Ng
Pg
See the "Optical Fiber Selection Chart" in the "TECHNICAL INFO" section for detailed fiber type specifications.
Product Description
The Dry Block, Sunlight Resistant Indoor/Outdoor Tight Buffer Riser Rated
Cable line offers the system designer the ultimate in premises optical fiber
cable utility. These cables can be installed in open spaces, trays, conduits,
inner-ducts, trenches, steam tunnels and building riser locations. These
cables incorporate the latest in dry water blocking technology. This system
of water blocking eliminates the need to clean off the traditional gel-based
water blocking compounds found in loose-tube cables. In addition, breakout
kits and or other special termination equipment associated with loose tube
Outside Plant (OSP) cables are not required. The outer jacket is comprised
of a rugged UL Listed, sunlight resistant, black polymer that allows for the
cable to be exposed to long-term direct sunlight without the concern of
material degradation. All fiber types are available, including 50/125 μm,
62.5/125 μm and single mode.
Cable line offers the system designer the ultimate in premises optical fiber
cable utility. These cables can be installed in open spaces, trays, conduits,
inner-ducts, trenches, steam tunnels and building riser locations. These
cables incorporate the latest in dry water blocking technology. This system
of water blocking eliminates the need to clean off the traditional gel-based
water blocking compounds found in loose-tube cables. In addition, breakout
kits and or other special termination equipment associated with loose tube
Outside Plant (OSP) cables are not required. The outer jacket is comprised
of a rugged UL Listed, sunlight resistant, black polymer that allows for the
cable to be exposed to long-term direct sunlight without the concern of
material degradation. All fiber types are available, including 50/125 μm,
62.5/125 μm and single mode.
Applications
• Intra/inter-building backbones
• Trench/conduit/duct/tray pathways
• Dry or wet locations
• Trench/conduit/duct/tray pathways
• Dry or wet locations
Features
Benefits
• Exceeds ANSI/TIA-568-C.3
optical performance
• Future-proof fiber performance
for current and future multi-
gigabit applications
• Dry-block design meets
Telcordia gR-20-CORE water
block requirements
• Cable integrity maintained
even if damage occurs to
protective layers
• 900 μm tight-buffered fibers
• Attaches directly
to mechanical connectors
• UL/NEC Listed OFNR
• Eliminates the need to purchase
separate cables for OSP and
indoor/riser applications
• All dielectric
• No additional grounding materials
need to be purchased
• Jacket rip cord
• Saves time in cable preparation
• Black, UL Listed sunlight
resistant outer jacket
• Long periods of direct sunlight
exposure will not damage cable
Flame Retardant PVC Jacket
Flame Retardant, Chemical and
Sunlight Resistant PVC Jacket
Buffered Optical Fiber
Water Blocking Dielectric
Aramid Strength Members
Water Blocking Tape
Rip Cord
Central Strength Member