4.  Checking of drawing drain hose 
•  Connect the separate drain hose to the drain hose 
that is attached to the indoor unit.
 
•  For keeping the smooth flowing of condensed water 
the drain hose should be inclined as shown in figure 
below.
 
 
 
 
WARNING 
• 
Be sure that the hose is not loosely connected or 
bent.
 
 
 
CAUTION 
• 
Please ensure the smooth flow of condensed 
water of the indoor unit during installation. 
(Carelessness may result in water leakage.) 
 
10.1.3 
INSTALLATION OF FLOOR TYPE 
INDOOR (RAF-RPA)
 
Please read the safety precautions carefully before 
operating the unit. The contents of this section are vital to 
ensure safety. Please pay special attention to the following 
signs. 
WARNING  Incorrect methods of installation may 
cause death or serious injury 
CAUTION   Improper installation may result in 
serious consequences. 
 Make sure to connect earth wire 
 This sign indicates prohibition 
Be sure that the unit operates in proper condition after 
installation. Explain to customer the proper way of operating 
the unit as described in the user’s guide. 
 
 WARNING 
• 
Please request your sales agent or qualified 
technician to install your unit. Water leakage, short 
circuit of fire may occur if you do the installation 
work yourself. 
• 
Please  observe the instructions stated in the 
installation manual during the process of installation. 
Improper installation may cause water leakage, 
electric shock and fire. 
• 
Make sure that the units are mounted at locations 
which are able to provide full support of the weight of 
the units. If not, the units may collapse and impose 
danger. 
• 
Observe the rules and regulations of the electrical 
installation and the methods described in the 
installation manual when dealing with the electrical 
work. Use power cables approved by the authorities 
of your country. 
• 
Be sure to use the specified wire for connecting the 
indoor and outdoor units. Please ensure that the 
connections are tight after the conductors of the wire 
are inserted into the terminals. Improper insertion 
and loose contact may cause over-heating and fire. 
• 
Please use the specified piping set for the correct 
refrigerant gas. Otherwise, this may result in broken 
copper pipes or faults 
• 
When installing or removing an air conditioner, don 
not allow air or moisture to remain in the 
refrigeration cycle. Otherwise, pressure in the 
refrigeration cycle may become abnormally high 
may cause a rupture. 
• 
Be sure to ventilate fully in case refrigerant gas 
leaks while at work. If the refrigerant gas comes into 
contact with fire, poisonous gas might be 
discharged. 
• 
After completion of installation work, check to make 
sure that there is no refrigeration gas leakage. If the 
refrigerant gas leaks into the room, coming into 
contact with fire in a fan-driver heater, space heater, 
etc; poisonous gas may be emitted. 
• 
Unauthorized modifications to the air conditioner 
may be dangerous. If a breakdown occurs, please 
contact a qualified air conditioner technical or 
electrician. Improper repairs may result in water 
leakage, electric shock and fire. 
• 
Be sure to connect the earth wire from power 
supply wire to the outdoor unit and between the 
outdoor and indoor unit. Improper grounding may 
cause electric shock. 
 
 
 
Horizontal air deflector (Air intake) 
Horizontal air deflector (Air outlet) 
Signal receiver 
Above 200mm 
Above 
100mm 
Above 150mm 
Lattice door 
30mm 
Air conditioner 
Bad 
Bad 
Bad 
Bad 
Condensed 
water pond 
Bending 
upwards 
Ditch 
Condensed 
water pond