Cypress Semiconductor CY3280-MBR3 データシート

ページ / 17
CY8CMBR3002, CY8CMBR3102
CY8CMBR3106S, CY8CMBR3108
CY8CMBR3110, CY8CMBR3116 Datasheet
Document Number: 001-85330 Rev. *G 
Page 12 of 37
Device Feature Details
Automatic Threshold
Dynamically sets all threshold parameters for button sensors, 
depending on the noise in the environment. 
Applicable only to button sensors.
Mutually exclusive from the EMC feature. If EMC is enabled, 
automatic threshold is automatically disabled. 
Sensitivity Control
This feature allows specification of the minimum change in 
sensor capacitance that can trigger a sensor state change (OFF 
to ON or vice-versa).
Sensitivity can be specified individually for each CapSense 
button and slider.
Sensitivity can be specified as one of the four available values: 
0.1 pF, 0.2 pF, 0.3 pF, and 0.4 pF.
Higher sensitivity values can be used for thick overlays or small 
button diameters.
Lower sensitivity values should be used for large buttons or 
thin overlays to minimize power consumption.
Sensor Auto Reset
This feature resets the CapSense sensors to the OFF state after 
a specific time period, even though they continue to be activated.
Resets the sensor baseline to the current raw count after a 
specific time period, even though the sensors continue to be 
activated. 
Prevents a stuck sensor when a metal object is placed close 
to that sensor.
The Auto Reset period can be set to 5 or 20 seconds and can 
be configured through two global settings provided in the 
Global setting for all proximity sensors
Global setting for all CapSense buttons and slider segments
The guard sensor does not undergo Auto Reset.
Figure 2.  Example of Button Auto Reset on GPO0 (DC Active 
Low Output)
Table 7.  Device Feature Benefits
Feature
Benefits
Automatic Threshold
Automatically tunes all the threshold 
parameters of the sensors for 
different noise settings
Sensitivity Control
Maintains optimal button 
performance for different overlay 
and noise conditions
Sensor Auto Reset
Recalibrates the sensor when a 
stuck-sensor (fault) condition 
occurs, and avoids invalid sensor 
output status to host
Noise Immunity
Provides immunity against external 
noise and the ability to detect 
touches without false trigger in noisy 
environments
Flanking Sensor 
Suppression (FSS)
Avoids multiple button triggers in a 
design with closely spaced buttons
Host Controlled GPOs
GPO pins, which can be controlled 
by the host processor through I
2
C
LED On time
GPO output status stays ON for a 
set duration after the touch is 
released to provide better visual 
feedback to the user
Toggle
Sensor output status toggles on 
every sensor activation to mimic the 
mechanical toggle button 
functionality
Buzzer Signal Output
Provides audio feedback on button 
touch
Host Interrupt 
Provides interrupt to host when 
there is a change in sensor status
Latch Status Output
Latches the sensor status changes 
in the register until the host reads 
the activated sensor status; this 
ensures that the sensor status is 
always read by the host even if the 
host is late to service the host 
interrupt signal from CY8CMBR3xxx 
Analog Voltage Output
Indicates the button status through 
voltage levels 
System Diagnostics
Supports production testing and 
debugging
Low-Power Sleep Mode 
and Deep Sleep Mode
Reduces power consumption
CSx
GPOx
Auto Reset Period
GPOx turns inactive as Auto 
Reset period expired for CSx
Sensor 
Activated
Touch on Sensor