Texas Instruments CC2650DK ユーザーズマニュアル

ページ / 1570
General-Purpose Timer Registers
13.5.1.25 TAPV Register (Offset = 64h) [reset = X]
TAPV is shown in
and described in
.
Timer A Pre-scale Value This register shows the current value of the Timer A free running pre-scaler in
the 16-bit mode. Note: When the alternate timer clock (TIMCLK) is enabled; a read of a timer value will
return the current count 1.
Figure 13-33. TAPV Register
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
RESERVED
PSV
R-X
R-X
Table 13-32. TAPV Register Field Descriptions
Bit
Field
Type
Reset
Description
31-16
RESERVED
R
X
Software should not rely on the value of a reserved. Writing any
other value than the reset value may result in undefined behavior.
15-0
PSV
R
X
GPT Timer A Pre-scaler Value
1118
Timers
SWCU117A – February 2015 – Revised March 2015
Copyright © 2015, Texas Instruments Incorporated