Texas Instruments CC2650DK ユーザーズマニュアル

ページ / 1570
Random Number Generator
16.7.1.9 FROEN Register (Offset = 20h) [reset = X]
FROEN is shown in
and described in
FRO Enable
Figure 16-12. FROEN Register
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
RESERVED
FRO_MASK
R-X
R/W-FFFFFFh
Table 16-14. FROEN Register Field Descriptions
Bit
Field
Type
Reset
Description
31-24
RESERVED
R
X
Software should not rely on the value of a reserved. Writing any
other value than the reset value may result in undefined behavior.
23-0
FRO_MASK
R/W
FFFFFFh
Enable bits for the individual FROs. A '1' in bit [n] enables FRO 'n'.
Default state is all '1's to enable all FROs after power-up. Note that
they are not actually started up before the CTL.TRNG_EN bit is set
to '1'. Bits are automatically forced to '0' here (and cannot be written
to '1') while the corresponding bit in ALARMSTOP.FRO_FLAGS has
value '1'.
1172
Random Number Generator
SWCU117A – February 2015 – Revised March 2015
Copyright © 2015, Texas Instruments Incorporated