UARTS Registers
19.7.1.10 IMSC Register (Offset = 38h) [reset = X]
IMSC is shown in
and described in
Interrupt Mask Set/Clear
Figure 19-13. IMSC Register
31
30
29
28
27
26
25
24
RESERVED
R/W-X
23
22
21
20
19
18
17
16
RESERVED
R/W-X
15
14
13
12
11
10
9
8
RESERVED
OEIM
BEIM
PEIM
R/W-X
R/W-X
R/W-X
R/W-X
7
6
5
4
3
2
1
0
FEIM
RTIM
TXIM
RXIM
RESERVED
CTSMIM
RESERVED
R/W-X
R/W-X
R/W-X
R/W-X
R/W-X
R/W-X
R/W-X
Table 19-13. IMSC Register Field Descriptions
Bit
Field
Type
Reset
Description
31-11
RESERVED
R/W
X
Software should not rely on the value of a reserved. Writing any
other value than the reset value may result in undefined behavior.
10
OEIM
R/W
X
Overrun error interrupt mask. A read returns the current mask for
UART's overrun error interrupt. On a write of 1, the mask of the
overrun error interrupt is set which means the interrupt state will be
reflected in MIS.OEMIS. A write of 0 clears the mask which means
MIS.OEMIS will not reflect the interrupt.
9
BEIM
R/W
X
Break error interrupt mask. A read returns the current mask for
UART's break error interrupt. On a write of 1, the mask of the
overrun error interrupt is set which means the interrupt state will be
reflected in MIS.BEMIS. A write of 0 clears the mask which means
MIS.BEMIS will not reflect the interrupt.
8
PEIM
R/W
X
Parity error interrupt mask. A read returns the current mask for
UART's parity error interrupt. On a write of 1, the mask of the
overrun error interrupt is set which means the interrupt state will be
reflected in MIS.PEMIS. A write of 0 clears the mask which means
MIS.PEMIS will not reflect the interrupt.
7
FEIM
R/W
X
Framing error interrupt mask. A read returns the current mask for
UART's framing error interrupt. On a write of 1, the mask of the
overrun error interrupt is set which means the interrupt state will be
reflected in MIS.FEMIS. A write of 0 clears the mask which means
MIS.FEMIS will not reflect the interrupt.
6
RTIM
R/W
X
Receive timeout interrupt mask. A read returns the current mask for
UART's receive timeout interrupt. On a write of 1, the mask of the
overrun error interrupt is set which means the interrupt state will be
reflected in MIS.RTMIS. A write of 0 clears the mask which means
this bitfield will not reflect the interrupt. The raw interrupt for receive
timeout RIS.RTRIS cannot be set unless the mask is set (RTIM = 1).
This is because the mask acts as an enable for power saving. That
is, the same status can be read from MIS.RTMIS and RIS.RTRIS.
5
TXIM
R/W
X
Transmit interrupt mask. A read returns the current mask for UART's
transmit interrupt. On a write of 1, the mask of the overrun error
interrupt is set which means the interrupt state will be reflected in
MIS.TXMIS. A write of 0 clears the mask which means MIS.TXMIS
will not reflect the interrupt.
1346
Universal Asynchronous Receivers and Transmitters (UARTS)
SWCU117A – February 2015 – Revised March 2015
Copyright © 2015, Texas Instruments Incorporated