Settings
CAN Base ID
(available since firmware 5.01)
Possible settings: 
0x000 (0000) 
...
 0x7FC (2044)
Default setting: 
0x000 (0000)
Belongs to: CAN interface card IF-C1
Explanation: this adjusts the base ID for the CAN ID sy-
stem which uses three IDs (see above at CAN ID System). 
With the three IDs per unit, the system is compatible to 
Vector software and the so-called CAN databases (*.dbc). 
The base ID is adjustable in steps of four. Also see the 
further  documentation  for  the  Vector  system,  which  is 
included with the databases.
Note:  this  setting  is  only  availabe,  if 
CAN  ID  System: 
Vector
 has been selected (see above).
CAN Broadcast ID
(available since firmware 5.01)
Possible settings: 
0x000 (0000) 
...
 0x7FF (2047)
Default setting: 
0x7FF (2047)
Belongs to: CAN interface card IF-C1
Explanation: the broadcast ID is an additonal ID of the 
Vector  ID  system.  It  is  generally  used  to  send  broad-
castmessages to multiple bus members at once. Those 
units, when addressed by this ID will act the same time, 
executing the same command, like setting current. With 
this ID, only settings or values can be sent and nothing 
can be queried.
Note:  this  setting  is  only  availabe,  if 
CAN  ID  System: 
Vector
 has been selected (see above).
CAN Bus terminate
Possible settings: 
yes
no
Default setting: 
yes
 (since firmware 5.01), else
 no
Belongs to: CAN interface card IF-C1
Explanation: defines, if the bus termination resistor on the 
CAN interface card is active or not. This is only required 
if the device is at the end of the CAN bus. By setting this 
parameter to 
yes
the resistor is activated, 
no
 deactivates 
it. In case you don‘t want to use this feature and instead 
want to install a custom resistor for bus termination, make 
sure that this setting is set to 
no
.
RS232 Baud rate
Possible settings: 
9600 Bd
19200 Bd
38400 Bd
57600 Bd
Default setting: 
57600 Bd
Belongs to: RS232 interface card IF-R1
Explanation:  determines  the  baudrate  (transmission 
speed) of the serial data transmission when using the 
serial RS232 interface card IF-R1. Make sure, that the 
other end of the serial connection operates at the same 
baudrate.