1.9.6  The control panel (HMI)
The HMI (
Human Machine Interface) consists of a display with touchscreen, two rotary knobs, a button and a 
USB-A port. 
1.9.6.1  Touchscreen display
The graphic touchscreen display is divided into a number of areas. The complete display is touch sensitive and 
can be operated by finger or stylus to control the equipment.
In normal operation the left hand side is used to show actual and set values and the right hand side to display 
status information:
Actual voltage display
Voltage set value input
Status area
Actual current display
Current set value input
Touch area for 
rotary knob assignment
Actual power display
Power set value input
Actual resistance value
Resistance set value input
Touch areas MENU 
and SETTINGS
Touch areas may be enabled or disabled:
  Black text or symbol = Enabled
  Grey text or symbol = Disabled
This applies to all touch areas on the main screen and all menu pages..
Actual / set values area (left hand side)
In normal operation the DC input values (large numbers) and set values (small numbers) for voltage, current and 
power are displayed. Resistance set value of the variable internal resistance is only displayed by active resistance 
mode. 
When the DC input is switched on, the actual regulation mode, 
CV, CC, CP or CR is displayed next to the cor-
responding actual values, as show in the figure above.
The set values can be adjusted with the rotary knobs next to the display screen or can be entered directly via the 
touchscreen. When adjusting with the knobs, pushing the knob will select the digit to be changed. Logically, the 
values are increased by clockwise turning and decreased by anti-clockwise turning.
General display and setting ranges:
Display
Unit
Range
Description
Actual voltage
V
0-125% U
Nenn
Actual value of DC input voltage
Set value voltage 
(1
V
0-100% U
Nenn
Set value for limiting the DC input voltage
Actual current
A
0.1-125% I
Nenn
Actual value of DC input current
Set value current 
(1
A
0-100% I
Nenn
Set value for limiting the DC input current
Actual power
W
0-125% P
Nenn
Calculated actual value of input power, P = U * I
Set value power 
(1
W
0-100% P
Nenn
Set value for limiting DC input power
Actual resistance
Ω
0...99.999 Ω
Calculated actual internal resistance, R = U
IN
 / I
IN
Set value internal resistance
(1
Ω
x
(2
-100% R
Max
Set value for the target internal resistance
Adjustment limits
A, V, kW 0-102% nom
U-max, I-min etc., related to the physical values
Protection settings
A, V, kW 0-110% nom
OVP, OCP etc., related to the physical values
(1 
Valid also for values related to these physical units, such as OVD for voltage and UCD for current
(2