Ea Elektro Automatik EA Elektro-Automatik EA-ELR 9250-140 3U Electronic Load 0 - 140 A 0 - 250 Vdc 0 - 7000 W 33200406 データシート

製品コード
33200406
ページ / 160
Page 61
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
ELR 9000 Series
Schematic diagram:
Application and result:
O
ffse
t
t
A
A
m
plit
ud
e
t1
t2
A triangular wave signal for input current (direct) or input 
voltage (indirect) is generated. The positive and negative 
slope times are variable and can be set independently.
The offset shifts the signal on the Y-axis.
The sum of the intervals t1 and t2 gives the cycle time 
and its reciprocal is the frequency.
Example: a frequency of 10 Hz is required and would 
lead to periodic duration of 100 ms. This 100 ms can 
be freely allocated to t1 and t2, e.g. 50 ms:50 ms (isos-
celes triangle) or 99.9 ms:0.1 ms (right-angled triangle 
or sawtooth).
3.9.7  Rectangular function
The following parameters can be configured for a rectangular wave function:
Value
Range
Description
I(A), U(A)
0...(Nominal value - (Off)) of U, I A = Amplitude of the signal to be generated
I(Off), U(Off) 0...(Nominal value - (A)) of U, I
Off = Offset, based on the foot of the rectangular wave
t1
0.1 ms...36000 s
Time (pulse width) of the upper level (amplitude)
t2
0.1 ms...36000 s
Time (pause width) of the lower level (offset)
Schematic diagram:
Application and result:
O
ffs
et
t
A
A
m
plit
ude
t1
t2
A rectangular or square wave signal for input current 
(direct) or input voltage (indirect) is generated. The 
intervals  t1  and  t2  define  how  long  the  value  of  the 
amplitude (pulse) and how long the value of the offset 
(pause) are effective.
The offset shifts the signal on the Y axis.
Intervals t1 and t2 can be used to define a duty cycle. 
The sum of t1 and t2 gives the period and its reciprocal 
is the frequency. 
Example: a rectangular wave signal of 25 Hz and a 
duty cycle of 80% are required. The sum of t1 and t2, 
the period, is 1/25 Hz = 40 ms. For a duty cycle of 80% 
the pulse time (t1) is 40 ms*0.8 = 32 ms and the pause 
time (t2) is 8 ms