1.7.5  Alarm signals
The equipment offers various possibilities for signalling alarm conditions, however, not for danger situations. The 
signals may be optical (on the display as text) acoustic (piezo buzzer) or electronic (pin/status output of an analog 
interface). All alarms will cause the device to switch off the DC input.
The meaning of the signals is as follows: 
Signal 
OT
(OverTemperature)
Overheating of the device
DC input will be switched off
Non-critical
Signal 
OVP
(OverVoltage)
Overvoltage shutdown of the DC input occurs due to high voltage entering the device
Critical! The device and/or the load could be damaged
Signal 
OCP
(OverCurrent)
Shutdown of the DC input due to excess of the preset limit
Non-critical, protects the source from excessive current drain
Signal 
OPP
(OverPower)
Shutdown of the DC input due to excess of the preset limit
Non-critical, protects the source from excessive power drain
Signal 
PF
(Power Fail)
DC input shutdown due to AC undervoltage or defect in the AC input
Critical on overvoltage! AC mains input circuit could be damaged
1.8 
Technical data
1.8.1  Approved operating conditions
Use only inside dry buildings
Ambient temperature 0-50 °C
Operational altitude: max. 2000 m above sea level
Max 80% RH up to 30 °C, linear decrease to 50% RH at 50 °C
1.8.2  General technical data
Display:     
Colour TFT touch screen with gorilla glass, 4.3”, 480pt x 272pt, capacitive  
Controls:    
2 rotary knobs with pushbutton functions, 1 button
The nominal values for the device determine the maximum adjustable ranges.