Ea Elektro Automatik EA Elektro-Automatik EA-ELR 9250-140 3U Electronic Load 0 - 140 A 0 - 250 Vdc 0 - 7000 W 33200406 データシート

製品コード
33200406
ページ / 160
Page 7
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
ELR 9000 Series
1.7 
Safety
1.7.1  Safety notices
Mortal danger - Hazardous voltage
Electrical equipment operation means that some parts will be under dangerous voltage. 
Therefore all parts under voltage must be covered!
All work on connections must be carried out under zero voltage (input not connected to 
voltage sources) and may only be performed by qualified and informed persons. Improper 
actions can cause fatal injury as well as serious material damage.
Never touch cables or connectors directly after unplugging from mains supply as the 
danger of electric shock remains.
This electronic load device uses an inverter and in case of a failure the intermediate 
circuit voltage can be present on the DC input, even if there is no voltage source con-
nected - it is recommended to never touch the metal parts of the DC input terminals 
with bare hands!
The equipment must only be used as intended
The equipment is only approved for use within the connection limits stated on the product label.
Do not insert any object, particularly metallic, through the ventilator slots
Avoid any use of liquids near the equipment. Protect the device from wet, damp and conden-
sation.
For power supplies and battery chargers: do not connect users, particularly low resistance, to 
devices under power; sparking may occur which can cause burns as well as damage to the 
equipment and to the user. 
For electronic loads: do not connect power sources to equipment under power, sparking may 
occur which can cause burns as well as damage to the equipment and to the source. 
ESD regulations must be applied when plugging interface cards or modules into the relative slot
Interface cards or modules may only be attached or removed after the device is switched off. 
It is not necessary to open the device.
Do not connect external power sources with reversed polarity to DC input or outputs! The 
equipment will be damaged.
For power supply devices: avoid where possible connecting external power sources to the DC 
output, and never those that can generate a higher voltage than the nominal voltage of the device.
For electronic loads: do not connect a power source to the DC input which can generate a volt-
age more than 120% of the nominal input voltage of the load. The equipment is not protected 
against over voltage and may be irreparably damaged.
Never insert a network cable which is connected to Ethernet or its components into the master-
slave socket on the back side of the device!
1.7.2  Responsibility of the user
The equipment is in industrial operation. Therefore the operators are governed by the legal safety regulations. 
Alongside the warning and safety notices in this manual the relevant safety, accident prevention and environmental 
regulations must also be applied. In particular the users of the equipment:
must be informed of the relevant job safety requirements
must work to the defined responsibilities for operation, maintenance and cleaning of the equipment
before starting work must have read and understood the operating manual
must use the designated and recommended safety equipment.
Furthermore, anyone working with the equipment is responsible for ensuring that the device is at all times techni-
cally fit for use.