Kuebler Kübler CODIX 529 Process display Codix 529 Assembly dimensions 45 x 22 mm 6.529.012.300 データシート

製品コード
6.529.012.300
ページ / 7
10
4.5 Min. value reset
Min. value can be reset by
pressing left button. (Cur-
rent value becomes new
min. value)
Min. value can’t be reset.
4.6 Decimal point
0
no decimal place
0.0
one decimal place
0.00
two decimal places
0.000
three decimal places
0.0000 four decimal places
The decimal point indicates
the number of decimal
places.
4.7 Min. input signal (only if input sig-
nal range is 4..20 mA or 2..10 V)
If the input signal level
at input range 4..20 mA
becomes below this
value, the display shows
„lo“.
If the input signal level
at input range 2..10 V
becomes below this
value, the display shows
„lo“.
a)
b)
This menu title allows a limitation of the
display range (have a look at 4.9 and 9.4)
Depending on chosen input
range a) or b) is selected.
4.8 Displayed value at min. input signal
A corresponding dis-
play value between -
19999 and 99999 can
be assigned to the
lowest input signal.
The decimal point’s
position is considered.
4.9 Max. input signal (only if input sig-
nal range is 4..20 mA or 2..10 V)
If the input signal level at
input range 4..20 mA beco-
mes above this value, the
display shows „high“.
If the input signal level at
input range 2..10 V beco-
mes above this value, the
display shows „high“.
Depending on chosen input
range a) or b) is selected.
a)
b)
This menu title allows a limitation of the
display range (have a look at 4.7 and 9.4)
4.10 Displayed value at max. input signal
A corresponding display
value between -19999
and 99999 can be assi-
gned to the highest input
signal. The decimal
point’s position is consid-
ered.