5. Thermostat
6. Remote control
The sequence diagram below summarizes the interaction between the devices.
Sections that follow provide additional information about each device application.
Figure 7-1. Home Automation application interactions sequence diagram.
Occupancy
Sensor
Dimmable
Light
Dimmer
Switch
Remote
Control
Read Attribute:
Main Voltage
Report Attribute:
Temperature
APS Ack
Read Attribute
response
Once per 10
seconds
Once per 10
seconds
Occupancy
Sensing
attribute
toggle
Once per 20
seconds
Once per 10
seconds
Report Attribute:
Relative Humidity
APS Ack
Thermostat
Report Attribute:
Occupancy
Sensing
APS Ack
Once per 4
seconds
Occ
SenInd
Default Response
Setpoint
RaiseLower
Command
LT
Changing
Report Attribute:
Local
Temperature
Once per 4
seconds
APS Ack
Report Attribute:
On/Off Value
APS Ack
Once per 4 seconds
Report Attribute:
Level Control Current Level
APS Ack
Once per 4 seconds
Clusters binding
Report Attribute:
Occupancy
Sensing
De
m
o
Lo
op
APS Ack
7.1 Security settings
To join and operate as part of an HA network, a device needs to know the extended
address of the trust center prior to network join. In addition, each HA device has a
predefined link key known to the trust center. This security mechanism is identical to
the standard security mode with link keys mode used in SE networks.
7.2 Occupancy sensor
For supported platforms with buttons, occupancy sensor state can be controlled
manually by pressing a button. On XMEGA-STK600 and megaRF-STK600, when the
SW0
button is pressed, the sensor’s state is toggled. For supported platforms with no
buttons, the state is toggled automatically by the application every 20 seconds.
Occupancy sensor binds with remote control and dimmable light devices. Once
Occupancy sensor binds with remote control and dimmable light devices. Once
bound to, occupancy sensor will report its state to remote control and light devices
every four seconds. The standard ZCL reporting mechanisms are used for reporting.