Sample applications 
 
4.2 Factory door 
LOGO!Soft Comfort Online Help 
Operating Instructions, 06/2014 
183
 
You can invert output Q3 to use output messages at Q4. Relay Q4 only drops out if main 
power is lost or if there is a fault in the system. The output can then be used for a remote 
message. 
4.2 
Factory door 
Requirements for a gate control system 
In many cases a factory entrance is closed with roll gates. Those gates are only opened 
when vehicles need to enter or leave the factory grounds. The gate is controlled by a 
gatekeeper. 
●  The sliding gate is opened and closed by means of a pushbutton control in the 
gatehouse. The gatekeeper can monitor the gate operation. 
●  The roll gate is normally fully opened or it is closed. However, gate movements can 
always be interrupted. 
●  A flashing light is activated five seconds before the gate moves and while the gate is in 
motion. 
●  A safety pressure strip ensures that people are not injured and that no objects are 
trapped and damaged when the gate is closing. 
Standard solution 
There are many different control systems for operating automatic gates. The OPEN and 
CLOSE buttons initiate gate movements in the relevant direction, provided it is not already 
moving in the opposite direction. Movement of the gate is terminated either by means of the 
STOP button or the relevant limit switch. 
LOGO!Soft Comfort solution 
A LOGO! circuit provides a further feature compared to standard controls: The actuation of a 
safety bar interrupts the closing motion of the gate. Five seconds before the gate opens or 
closes, a flashing light is activated and signals the start of the movement. It continues 
flashing until the gate has stopped. 
In contrast to standard solutions, LOGO! offers an easy and economic means of modifying 
the control system.