Reference material 
 
5.3 Special functions 
 
LOGO!Soft Comfort Online Help 
330
 
Operating Instructions, 06/2014 
 
Message area 
You arrange the message text in this area. Information entered in this area corresponds with 
that on the LOGO! onboard display. 
 
Insert button 
Button for inserting a selected block parameter into the message text. 
 
Block parameter area 
Shows the parameters of a block selected from the block area which you can output in the 
message text. 
 
General parameter area 
Shows general parameters such as the current date. 
To arrange the message text 
1.  From the "Block" area, select the block whose parameters you want to output. 
2.  Drag and drop the parameters required from the block parameters to the messages area. 
You may also use the "Insert" button to do so. 
3.  In the messages area, you can add parameter data as required. 
Simulation mode 
5.3.6.6 
Message text (LOGO! 0BA2 and LOGO! 0BA3) 
 
 
 
The message text is only available for devices as of hardware series 0BA2. 
Short description 
Display of a configured message text in RUN mode. 
 
Connection 
Description 
Input En 
The message text is output with a 0 to 1 transition at input En (Enable). 
Parameter P 
P is the priority of the message text. 
0 is the lowest, 9 the highest priority. 
Parameter 
Par: Parameter or actual value of another, already programmed function 
(see "Displayable parameters or actual values") 
Output Q 