Siemens SPS starter kit 6ED1057-3BA00-0AA8 12 Vdc, 24 Vdc 6ED1057-3BA00-0AA8 データシート

製品コード
6ED1057-3BA00-0AA8
ページ / 378
 
Reference material 
 
5.3 Special functions 
LOGO!Soft Comfort Online Help 
Operating Instructions, 06/2014 
331
 
Description of the function 
In RUN mode, a 0 to 1 transition of the signal at input En triggers the output of your 
configured message text on the display. The message text is closed after a 1 to 0 transition 
at input En and if the acknowledgment attribute is not set. If the acknowledgment attribute is 
set, the message text is not closed until input En=0 and the message is acknowledged at the 
LOGO! with OK. The status at output Q remains 1 as long as the message text is displayed. 
Of several message text functions triggered with En=1, the one with the highest priority is 
displayed. Low-priority messages can also by displayed by pressing the   button on the 
LOGO!. 
You can switch between the standard display and the message text display by means of the 
LOGO! buttons   and  . 
Restrictions 
Up to five message text functions are available. 
Particular characteristics to be noted when configuring 
The message text can be configured in the block properties dialog. You can enter up to four 
lines for each message text (the text display of the LOGO! has four rows) and set the priority. 
You can move to the next line using the cursor keys or the mouse. Hit the [ENTER] key to 
confirm all your entries in the block properties dialog and to close the dialog. 
You may also enter the actual values of other blocks in the text lines. To do so, select the 
relevant block from the Block dialog. A Parameter dialog opens to display a list of all 
parameters available for the selected block. The block parameter you select in this dialog is 
written to the selected text line. The actual parameter value is now included when you call 
the message text. 
Set the "Acknowledge message" attribute to specify whether a message is be acknowledged 
before it is closed. 
Simulation mode 
5.3.6.7 
Softkey