Siemens SPS starter kit 6ED1057-3BA00-0AA8 12 Vdc, 24 Vdc 6ED1057-3BA00-0AA8 データシート

製品コード
6ED1057-3BA00-0AA8
ページ / 344
 
Technical data 
 
A.7 Technical data: LOGO! DM8 24R and LOGO! DM16 24R 
LOGO! 
Manual, 06/2014, A5E33039675 
303
 
 
LOGO! 24RCE 
LOGO! 24RCEo 
Continuous current I
th
 
Recommended range of application ≥ 100 mA at 
12 VAC/VDC 
Max. 10 A per relay 
Surge current 
Max. 30 A 
Incandescent lamp load (25000 switching 
cycles) at 
1000 W 
Fluorescent tubes with ballast (25000 
switching cycles) 
10 x 58 W 
Fluorescent tubes, conventionally 
compensated (25000 switching cycles) 
1 x 58 W 
Fluorescent tubes, uncompensated (25000 
switching cycles) 
10 x 58 W 
Derating 
None; across the entire temperature range 
Short circuit-proof cos 1  
Power protection B16, 600 A 
Short circuit-proof cos 0.5 to 0.7 
Power protection B16, 900 A 
Parallel output circuits for power increase 
Not permitted 
Protection of output relay  
(if desired) 
Max. 16 A, 
characteristic B16 
Switching rate  
Mechanical 
10 Hz 
Ohmic load/lamp load 
2 Hz 
Inductive load 
0.5 Hz 
Notice: For fluorescent lamps with capacitors, you must consider the technical data of 
fluorescent lamp ballasts. If the current exceeds the maximum allowed surge current, 
appropriate contactor relays must switch the flourescent lamps.  
The data was determined with the following devices: 
●  Siemens fluorescent tubes 58 W VVG 5LZ 583 3-1 uncompensated. 
●  Siemens fluorescent tubes 58 W VVG 5LZ 583 3-1 parallel compensated with 7 μF. 
●  Siemens fluorescent tubes 58 W VVG 5LZ 501 1-1N with ballast. 
A.7 
Technical data: LOGO! DM8 24R and LOGO! DM16 24R 
 
 
LOGO! DM8 24R 
LOGO! DM16 24R 
Power supply 
Input voltage 
24 VAC/VDC 
24 VDC 
Permissible range 
20.4 VAC to 26.4 VAC 
20.4 VDC to 28.8 VDC 
 
20.4 VDC to 28.8 VDC 
Reverse polarity protection 
- - 
Yes 
Permissible mains frequency 
47 Hz to 63 Hz 
- -