 Server System R2000BB Product Family TPS 
18 
 
Revision 2.0 
 
 
3.6  Optional Chassis Grounding Support 
The system provides 10-32 threaded grounding studs on the back panel of the chassis, allowing for optional 
system grounding via a grounding strap.  
 
Figure 20. Chassis Grounding Studs 
 
3.7  AC Input Requirement 
3.7.1 
Power Factor 
The power supply must meet the power factor requirements stated in the Energy Star
®
 Program Requirements 
for Computer Servers. These requirements are stated below. 
Output power 
10% load 
20% load 
50% load 
100% load 
Power factor 
> 0.65 
> 0.80 
> 0.90 
> 0.95 
Tested at 230Vac, 50Hz and 60Hz and 115VAC, 60Hz 
 
3.7.2 
AC Input Voltage Specification 
The power supply must operate within all specified limits over the following input voltage range.  Harmonic 
distortion of up to 10% of the rated line voltage must not cause the power supply to go out of specified limits.  
Application of an input voltage below 85VAC shall not cause damage to the power supply, including a blown 
fuse. 
 
 
Table 10. AC Input Voltage Range 
PARAMETER 
MIN 
RATED 
VMAX 
Start up 
VAC 
Power Off 
VAC 
Voltage (110) 
90 Vrms 
100-127 Vrms 
140 Vrms 
85VAC +/-
4VAC 
70VAC +/-
5VAC 
Voltage (220) 
180 Vrms 
200-240 Vrms 
264 Vrms 
 
 
Frequency 
47 Hz 
50/60 
63 Hz 
 
 
1. 
Maximum input current at low input voltage range shall be measured at 90VAC, at max load. 
2. 
Maximum input current at high input voltage range shall be measured at 180VAC, at max load.   
3. 
This requirement is not to be used for determining agency input current markings.