Intel R2000BB4GS9 データシート

ページ / 89
Intel
®
 Server System R2000BB Product Family TPS 
20 
 
Revision 2.0 
 
Table 11.  AC Line Sag Transient Performance 
AC Line Sag (10sec interval between each sagging)  
Duration 
Sag 
Operating AC Voltage 
Line Frequency  Performance Criteria 
0 to 1/2 AC cycle 
95% 
Nominal AC Voltage ranges  50/60Hz 
No loss of function or performance 
> 1 AC cycle 
>30%  Nominal AC Voltage ranges  50/60Hz 
Loss of function acceptable, self recoverable 
 
Table 12.  AC Line Surge Transient Performance 
AC Line Surge  
Duration 
Surge  Operating AC Voltage 
Line Frequency 
Performance Criteria 
Continuous 
10% 
Nominal AC Voltages 
50/60Hz 
No loss of function or performance 
0 to ½ AC cycle 
30% 
Mid-point of nominal AC Voltages  50/60Hz 
No loss of function or performance 
 
3.7.8 
Susceptibility Requirements 
The power supply shall meet the following electrical immunity requirements when connected to a cage with an 
external EMI filter which meets the criteria defined in the SSI document EPS Power Supply Specification. For 
further information on Intel standards please request a copy of the Intel Environmental Standards Handbook 
 
Table 13.  Performance Criteria 
Level 
Description 
The apparatus shall continue to operate as intended. No degradation of performance. 
The apparatus shall continue to operate as intended. No degradation of performance beyond spec limits. 
Temporary loss of function is allowed provided the function is self-recoverable or can be restored by the operation of the 
controls. 
 
3.7.9 
  Electrostatic Discharge Susceptibility 
The power supply shall comply with the limits defined in EN 55024: 1998/A1: 2001/A2: 2003  using the IEC 
61000-4-2: Edition 1.2: 2001-04  test standard and performance criteria B defined in Annex B of CISPR 24. 
3.7.10 
Fast Transient/Burst 
The power supply shall comply with the limits defined in EN55024: 1998/A1: 2001/A2: 2003 using the IEC 
61000-4-4: Second edition: 2004-07 test standard and performance criteria B defined in Annex B of CISPR 24. 
3.7.11 
  Radiated Immunity 
The power supply shall comply with the limits defined in EN55024: 1998/A1: 2001/A2: 2003 using the IEC 
61000-4-3: Edition 2.1: 2002-09 test standard and performance criteria A defined in Annex B of CISPR 24. 
3.7.12 
  Surge Immunity 
The power supply shall be tested with the system for immunity to AC Unidirectional wave; 2kV line to ground 
and 1kV line to line, per EN 55024: 1998/A1: 2001/A2: 2003,  EN 61000-4-5: Edition 1.1:2001-04 . 
The pass criteria include: No unsafe operation is allowed under any condition; all power supply output voltage 
levels to stay within proper spec levels; No change in operating state or loss of data during and after the test 
profile; No component damage under any condition. 
 
The power supply shall comply with the limits defined in EN55024: 1998/A1: 2001/A2: 2003 using the IEC 
61000-4-5: Edition 1.1:2001-04 test standard and performance criteria B defined in Annex B of CISPR 24.