On the backside of each backplane are several connectors.  The following illustration identifies each. 
 
 
 
 
Label 
Description 
SMBus-Out cable connector for multi-backplane support 
4-port Mini-SAS cable connectors 
SMBus-In cable connector – From Server board or other backplane 
Power connector 
 
A and C – SMBus Cable Connectors – The backplane includes two 1x5 cable connectors used as a 
management interface between the server board and the installed backplanes.  In systems configured with 
multiple backplanes, a short jumper cable is attached between backplanes, with connector B used on the first 
board and connector D used on the second board, extending the SMBus to each installed backplane. 
 – Multi-port Mini-SAS Cable Connectors – The backplane includes two multi-port mini-SAS cable 
connectors, each providing SGPIO and I/O signals for four SAS/SATA hard drives on the backplane.  Cables 
can be routed from matching connectors on the server board, installed add-in SAS/SATA RAID cards, or 
optionally installed SAS expander cards for drive configurations of greater than 8 hard drives. 
D – Power Harness Connector – The backplane includes a 2x2 connector supplying power to the backplane. 
Power is routed to each installed backplane via a multi-connector power cable harness from the server board.  
6.1.2 
Cypress* CY8C22545 Enclosure Management Controller 
The backplanes support enclosure management using a Cypress* CY8C22545 Programmable System-on-
Chip (PSoC*) device.
 
The CY8C22545 drives the hard drive activity/fault LED, hard drive present signal, and 
controls hard drive power-up during system power-on.