Bryan Boilers HE-CLM Series プリント

ページ / 2
Bryan HE-CLM Series Gas Fired Flexible Tube Boilers
Form No. 6700 
©2007 Bryan Steam LLC 
 Printed in USA
 
 
57-8782
Effi cient Water Tube Design
The Bryan Flexible Water Tube provides for extremely fast 
internal circulation for maximum heat transfer and operating 
effi ciency.
No “Thermal Shock”
The fl exibility of the bent water tube design eliminates all 
possible damage from “Thermal Shock” and from stresses 
caused by poor or unequal internal circulation. This is particu-
larly important with forced hot water heating systems designed 
for higher temperatures and greater temperature drops.
Natural Internal Circulation
The water tube design and the large water leg downcomers 
provide adequate internal circulation without concern over ex-
terior pumping conditions. Low pressure drop through boiler.
Compact — Minimum Floor Space
Requires less fl oor space than most boilers — minimum 
boiler room size.
Shipped completely assembled and wired.
Tubes are easily removable and replaceable, requiring little 
service space.
Combination  thermometer  and pres-
sure gauge, ASME-rated boiler relief 
valve, water temperature control (240°F 
max. std.), high  limit  control, probe 
LWCO. Electronic combustion  safety 
control, automatic operating  gas valve, 
safety gas valve, pilot  solenoid  valve, 
pilot  ignition  assembly, main  manual 
gas shut-off valve, pilot cock, pilot 
and main  gas pressure  regulators, air 
safety switch, control panel, all controls 
installed  and  wired.
Dimensions and specifi cations are subject to change without notice. Consult factory for certifi ed dimensions.
Bryan Steam LLC — Leaders Since 1916
  
783 N. Chili Ave., Peru, Indiana 46970 U.S.A.
Phone: 765-473-6651 • Internet:www.bryanboilers.com  
Fax: 765-473-3074  • E-mail: bryanboilers@iquest.net
OPTIONAL CONSTRUCTION:
Optional construction to ASME Power 
Boiler Code requirements for tempera-
tures exceeding  240°F  and/or  pres-
sure exceeding 160 psi to maximum 
of 285°F operating and 300°F design 
temperature and 250 psi.
When ordering, please specify:
1. Boiler 
size
2. Supply 
and 
return 
 temperatures 
required
3.  Boiler relief valve setting
4.  Type of fuel: natural, LP,
 
 or other gas
5.  Gas BTU content, specifi c 
gravity and pressure 
 available
6. Electric 
power 
voltage, 
 
phase and frequency
7.  Optional extra equipment 
 or 
construction
8. Special 
approvals 
required 
(UL, CUL, CSD-1, FM, or IRI)
9. Altitude
OPTIONAL EQUIPMENT:
1.  Manual reset high limit control
2.  Manual reset low water cutoff
3.  Auxiliary low water cutoff
4.  Combination low water cutoff 
 and 
feeder
5.  Alarm bells or horns
6.  UL, CUL, CSD-1, FM, IRI or other in-
surance approved control systems
7.  Control panel mounted on boiler
8.  Indicating lights, as desired
9.  Lead-lag systems for two or more 
boilers with or without outdoor 
 reset 
control
 
STANDARD EQUIPMENT:
Bryan HE-CLM Series Boilers Standard and Optional Equipment
10. Draft control system
11. Special construction
 
and knocked down
NOTE:  * Gas train and control location dimensions will vary depending on job specifi cations and conditions.
BOILER DIMENSIONS in inches (cm)
 
 A 
  D 
   E* 
F     
 G 
 I 
 J 
L
    BOILER 
Length 
Width 
Height 
 
Overall 
 Gas Train 
Supply   Return 
Flue 
Flue
 Min. 
Tube 
Clearance 
for 
Floor 
to 
    MODEL 
Of 
Outside 
Over 
 
Length  
Connection  Nozzle  Nozzle  Size  Location
 Removal 
Servicing 
Flow
   NUMBER 
Jacket 
Jacket 
Jacket 
 
 
 
 
  
  
Clearance 
Burner 
Nozzle
HE-CLM90-W
  
41 
7
/
16 
34 
5
/
72 
1
/
16
 69  
7
/
16
 
1 NPT 
3 NPT 
3 NPT 
10
 
20 
11
/
16 
30 36
 
76 
3
/
16
 
(105.24) (87.94) (180.03) 
(176.98)  (2.54) 
(7.62)  (7.62) (25.40) (52.54)  (76.2) 
(91.44)  (193.51)
HE-CLM120-W
  
50 
11
/
16 
34 
5
/
72 
1
/
16
 78 
11
/
16
 
 1
1
/
 NPT 
3 NPT 
3 NPT 
10
 
25 
5
/
16 
30 36
 
76 
3
/
16
 
(128.74) (87.94) (180.03) 
(199.86)  (3.18) 
(7.62)  (7.62) (25.40) (64.29)  (76.2) 
(91.44)  (193.51)
HE-CLM150-W
  
59 
11
/
16 
34 
5
/
72 
1
/
16
 87 
11
/
16
 
 1
1
/
 NPT 
3 NPT 
3 NPT 
12
 
29 
13
/
16 
30 36
 
76 
3
/
16
 
(151.60) (87.94) (180.03) 
(212.72)  (3.81) 
(7.62)  (7.62) (30.48) (75.72)  (76.2) 
(91.44)  (193.51)
HE-CLM180-W
 69 
1
/
34 
5
/
72 
1
/
16
 97 
1
/
8
 
2
 
 NPT 
3 NPT 
3 NPT 
14
 
34 
9
/
16 
30 36
 
76 
3
/
16
 
(175.57) (87.94) (180.03) 
(246.69)  (5.08) 
(7.62)  (7.62) (35.56) (87.78)  (76.2) 
(91.44)  (193.51)
HE-CLM210-W
 78 
3
/
34 
5
/
72 
1
/
16
 106 
3
/
8
 
2 NPT 
3 NPT 
3 NPT 
14
 
39 
3
/
16 
30 36
 
76 
3
/
16
 
(199.07) (87.94) (180.03) 
(270.19)  (5.08) 
(7.62)  (7.62) (35.56) (99.53)  (76.2) 
(91.44)  (193.51)
HE-CLM240-W
 88
 
34 
5
/
72 
1
/
16
 
116 
2 NPT 
3 NPT 
3 NPT 
16
 
44
 
30 36
 
76 
3
/
16
 
(223.52) (87.94) (180.03) 
(294.64)  (5.08) 
(7.62)  (7.62) (40.64) 
(111.76)  (76.2) 
(91.44)  (193.51)
HE-CLM270-W
 97
 
34 
5
/
72 
1
/
16
 
125 
2 NPT 
3 NPT 
3 NPT 
16
 
48
1
/
30 36
 
76 
3
/
16
 
(246.38) (87.94) (180.03) 
(317.50)  (5.08) 
(7.62)  (7.62) (40.64) 
(123.19)  (76.2) 
(91.44)  (193.51)
HE-CLM300-W
 106 
5
/
34 
5
/
72 
1
/
16
 134  
5
/
8
 2 
1
/
 NPT 
3 NPT 
3 NPT 
16
 
53 
3
/
16 
30 36
 
76 
3
/
16
 
(270.82) (87.94) (180.03) 
(341.91)  (6.35) 
(7.62)  (7.62) (40.64) (40.64)  (76.2) 
(91.44)  (193.51)