Whirlpool W10151595B ユーザーズマニュアル

ページ / 20
8
2. Remove neutral ground wire from external ground conductor 
screw. Connect neutral ground wire and the neutral wire 
(white or center wire) of power supply cord under center 
terminal block screw. Tighten screw.
D
E
A
B
C
A. External ground conductor screw - Dotted line shows 
position of NEUTRAL ground wire before being moved to 
center terminal block screw
B. Center terminal block screw
C. Neutral wire (white or center wire)
D. 3/4" (19 mm) UL listed strain relief
E. Neutral ground wire
3. Connect ground wire (green or bare) of power supply cord to 
external ground conductor screw. Tighten screw.
D
A
B
C
E
F
A. External ground conductor screw
B. Center terminal block screw
C. Neutral wire (white or center wire)
D. 3/4" (19 mm) UL listed strain relief
E. Neutral ground wire
F. Ground wire (green or bare) of power supply cord
4. Connect the other wires to outer terminal block screws. 
Tighten screws. 
5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer rear panel. 
Secure cover with hold-down screw.
7. You have completed your electrical connections. Now go to 
“Venting Requirements.”
4-wire connection: Direct Wire
IMPORTANT: A 4-wire connection is required for mobile homes 
and where local codes do not permit the use of 3-wire 
connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer 
can be moved if needed. 
Strip 5" (127 mm) of outer covering from end of cable, leaving 
bare ground wire at 5" (127 mm). Cut 1½" (38 mm) from 
3 remaining wires. Strip insulation back 1" (25 mm). Shape ends 
of wires into a hook shape.
     1
"
(25 mm)
       5
"
(127 mm)
When connecting to the terminal block, place the hooked end of 
the wire under the screw of the terminal block (hook facing right), 
squeeze hooked end together and tighten screw, as shown.
1. Remove center terminal block screw.
2. Remove neutral ground wire from external ground 
 
conductor screw. Connect neutral ground wire and 
 
place the hooked end (hook facing right) of the neutral 
 
wire (white or center wire) of direct wire cable under the 
center screw of the terminal block. Squeeze hooked ends 
together. Tighten screw.   
E
D
A
B
C
A. External ground conductor screw - Dotted line shows 
position of NEUTRAL ground wire before being moved to 
center terminal block screw
B. Center terminal block screw
C. Neutral wire (white or center wire)
D. 3/4" (19 mm) UL listed strain relief
E. Neutral ground wire