Loctite Dispense Valve 97114 ユーザーズマニュアル

ページ / 16
8
5. Dispensing (continued)
5.3 Shutdown
• To protect anaerobic products from curing, remove needle leaving Luer-Lok adapter exposed 
to air.
• To protect all other products from curing, place a protective cap on the dispensing needle.
• If for some reason the product being dispensed changes, contact your local salesperson for 
the recommended procedures.
5.4 Returning to Operation
• Remove the protective cap from the dispensing needle.
• If needed, purge the product feedline and dispensing valve of air (see Section 5.1).
Returning to Operation After Longer Periods of Non-use
• Remove the Luer-Lok tip cap.
• Purge the product feedline and dispensing valve of air (see Section 5.1).
• Perform the adjustment of the dispensing quantity according to Section 5.2.
5.5 Disassembling the Dispensing Valve
To replace the valve assembly or the actuator assembly, the bayonet lock of the dispensing valve
can easily be opened.
• Loosen the locking nut 6, turn the valve assembly by 90° counterclockwise and pull out.
• Reassemble the dispensing valve with the replaced part in the reverse order. In this case, 
there must not be any pneumatic pressure on the actuator.
Tighten the locking nut not only hand tight,
but also lightly with a wrench.
90
90