Loctite Dispense Valve 97114 ユーザーズマニュアル
9
Type of Malfunction
Possible Cause
Correction
No product or too little
– Product feedline not correctly connected.
• Correctly connect the product feedline.
product.
– Pneumatic hose not correctly connected.
• Correctly connect the pneumatic
feedline.
– Curing in the product feedline and/or in
• Replace the product hose and/or valve
the dispensing valve and/or in the
assembly of the dispensing valve
dispensing needle, when the adjustment
and/or dispensing needle.
knob 10 does not move for a start and
no product is dispensed.
no product is dispensed.
– Air in the product feedline and/or in
• Purge the product feedline, dispensing
the dispensing valve and/or in the
valve and dispensing needle of air
dispensing needle, when the adjustment
(section 5.1).
knob 10 moves for a start and no
product is dispensed.
product is dispensed.
– Controller incorrectly adjusted.
• Check the controller (see operating .
instruction for the controller).
Loctite Service.
Loctite Service.
– Product reservoir not switched on, or
• Check the reservoir (see operating
pressure is too low.
instruction for the product reservoir).
– Valve is closed.
• Increase stroke.
Air bubbles in
– Air in the dispensing
• Purge the product feedline,
product.
valve/product feedline.
dispensing valve and dispensing
needle of air (Section 5.1).
Product comes delayed
– Piston stroke (suck-back effect)
• Reduce the piston stroke.
after a start.
too large.
Product drips.
– Piston stroke (suck-back effect)
• Increase the piston stroke.
too small.
Dispensing valve does
– Air outlet choke 8 closed.
• Open the air outlet choke 8.
not open.
– Piston stroke set to O.
• Turn the adjustment knob 10 counter-
clockwise (+ direction).
Dispensing valve
– Air outlet choke 8 opened too wide.
• Adjust the air outlet choke 8.
opens too fast.
Dispensing valve
– Air outlet choke 9 closed.
• Open the air outlet choke 9.
does not close.
– Bayonet locking piece is not
• Tighten counter nut 6 with a wrench.
tight enough.
– Tubing not properly seated.
• Push tubing into fitting.
Dispensing valve
– Air outlet choke 9 opened too wide.
• Adjust the air outlet choke 9.
closes too fast.
6. Troubleshooting