Graco 308178H Dynamic Surge Suppressor ユーザーズマニュアル

ページ / 18
Instructions–Parts List
308178H
EN
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Dynamic Surge Suppressor
For use with double-diaphragm pumps and low-pressure reciprocating pumps.
For professional use only.
 
100 psi (0.7 MPa, 7 bar)  Maximum Fluid Working Pressure
100 psi (0.7 MPa, 7 bar)  Maximum Air Inlet Pressure
Model 224892, Series A
aluminum, with PTFE diaphragm
Model 224893, Series A
aluminum, with buna–N diaphragm
Model 224894, Series C
stainless steel, with PTFE diaphragm
Model 224895, Series C
stainless steel, with buna–N diaphragm
Table of Contents
Warnings
2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Installation
4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Operation and Maintenance
7
. . . . . . . . . . . . . . . . . . . 
Troubleshooting
8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Service
9
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Parts Drawing
12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Parts Lists
13
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Repair Kits
14
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Dimensional Drawing
15
. . . . . . . . . . . . . . . . . . . . . . . 
Technical Data
16
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Warranty
18
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Graco Phone Number
18
. . . . . . . . . . . . . . . . . . . . . . . 
WARNING
Hazard of Using Fluids Containing Haloge-
nated Hydrocarbons
Never use 1.1.1–trichloroethane, methylene
chloride, other halogenated hydrocarbon solvents
or fluids containing such solvents in aluminum
models 224892 or 224893.  Such use could result
in a chemical reaction, with the possibility of
explosion, which could cause death, serious bodily
injury, and/or substantial property damage.
Consult your fluid suppliers to ensure that the fluids
being used are compatible with aluminum and zinc
parts.
0903
ÄÄÄ