  1.  Remove all debris from pit before installation.
 
  2.  Use a deep cycle battery only. Refer to battery de scrip -
tions on page 6.
  3.  Be sure the pump is on a fi rm, level surface.
 
 4.  Install a serviceable check valve in the discharge 
line.
  5. Test the unit immediately after installation. Refer to 
STEP 6.
  1.  DO read all installation material with the pump and 
charger.                                                      
                      
  2.   DO inspect unit for any visible damage caused by ship-
ping.  Contact  dealer  if  unit  appears  to  be  damaged.              
                      
  3.  DO clean all debris from the pit.   
                      
  4.   DO always disconnect pump from power source before 
han dling. DO always connect to a separately protected 
and prop er ly grounded ground fault protected circuit. 
DO NOT ever cut, splice or damage power cord. DO 
Ten Helpful Hints For Easy Installation
Do’s  And  Don’t’s  For  Installing  A  Unit
NOT carry or lift pump by its power cord. DO NOT use 
an extension cord with the 
Aquanot
®
. DO NOT lengthen 
battery/pump leads.
                      
  5.  DO install union check valve (see step 3) in the dis-
 charge line. DO NOT use  a dis charge pipe smaller 
than the rec om mend ed pump discharge sizes. 
                      
  6.  DO test pump immediately after installation to be sure 
that the system is working properly. 
                      
  7.  DO review all applicable local and national codes and 
verify that the installation conforms to each of them. 
Performance Characteristics
  6.  The battery  & charger should be placed on a shelf.
 7. Check fl oat On/Off levels per STEP 2 of instructions.
  8.  Apply grease to the Positive and Negative terminals 
of the battery to prevent corrosion.
  9.  Check the battery water level once a month and add 
distilled water as necessary.
 10. Obtain model number, date code and in stal la tion in-
 struc tions be fore calling factory.                    
011922
  Note: 
Aquanot
®
 II (Model 585) data was de vel oped with the charger supplying DC power to the pump.
5
10
15
20
25
30
35
0
0
5
10
FLOW PER MINUTE
TO
TA
L DYNAMIC HEAD
15
20
GALLONS
LITERS
METERS
FEET
80
2
4
6
60
40
20
100
120
40
50
45
140
160
180
25
8
55
200
585
580
PUMP PERFORMANCE CURVE
MODEL 580/585
TOTAL DYNAMIC HEAD/FLOW
PER MINUTE
EFFLUENT AND DEWATERING
MODEL
Feet
Shut-off Head:
585
Meters
Gal.
Liters
5
1.5
49
186
10
3.0
36
136
15
4.6
25
95
20 ft.(6.1m)
Shut-off Head:
MODEL
15
10
5
Feet
17 ft.(5.2m)
Gal.
4.6
3.0
Meters
1.5
13
31
49
117
44
167
Liters
580