Sub Rate Data Ports
Model No.
Running Head
SRU port User Screens and Settings
SRU Ports
INTF
The Interface setting allows you to choose the protocol necessary for the terminal associated 
with this port. The choices are asyn (Asynchronous), and sync (Synchronous). If Synchronous 
transmission is selected, the choices for STOP, DATA and PAR will show as n/a (not 
applicable).
Asyn option provides asynchronous to synchronous conversion. The asyn option is a 
streamlined propriety algorithm which will increase the performance of the port.
COM CF
The Communication Configuration setting is a three-step process that allows you to choose 
the Data bits, Stop bits, and Parity to be used. The Data setting allows you to change the 
bits-per-byte number depending upon the type of terminal associated with this particular port. 
The options are 876, and 5.
The Stop bits option allows you to select the number of Stop bits that check data sampling for 
the terminal associated with this port. The options are 1 and 2.
The third choice is the Parity setting that changes the data parity for the terminal associated 
with this port. The options are noneoddevenspace and mark.
CTS
The Clear To Send (CTS) setting allows you to define how the port should respond upon 
receiving a Request to Send (RTS) from the attached DTE. This setting also allows you to 
change the delay time (in milliseconds) from when the port receives RTS until it issues CTS. 
The local option allows RTS to control CTS. The remote-local options allows RTS to control 
both the CTS of the local equipment and RLSD of the remote equipment. The options are 
perm (permanent), l0 (local–immediate), l30 (local - 30 ms), l60 (local - 60 ms), l100 (local 
- 100 ms), rl0 (remote/local - immediate), rl3 (remote/local - 30 ms), rl6 (remote/local - 60 
ms), rl10 (remote/local - 100 ms), and off.
TX CLK
The Transmit Clock setting allows you to choose the timing source for this port. The options 
are n/a if async interfacing is chosen and int (internal), if sync interfacing is chosen. The int 
setting uses the Integrated Access System as the clock source, and ext allows the DTE to 
generate transmit timing.