Zhone IMACS-200 ユーザーズマニュアル

ページ / 294
High Speed Data Ports
9-11
Table 9-5. Test Screen Option Settings and Defaults
BERT
The Bit Error Rate Tester (BERT) sends a data pattern and measures the bit error rate (BER) 
on the selected HSU port. The patterns that can be selected are offmark (1111), space (0000), 
1:1 (1010 alternating), 1:7 (0100-0000), 3:24qrss (quasi-random signal source), 
prb11(pseudorandom binary sequence), prb15 and prb20.
SYNC
The Synchronization field indicates if the integrated BERT has achieved synchronization 
either with itself via a remote loopback or with the remote test equipment. This is an 
information-only field; it is not user-configurable.
BE
The Bit Error (BE) field indicates the total number of bit errors logged. This is an 
information-only field; it is not user-configurable.
ES
The Errored Seconds (ES) field indicates the total number of seconds in which errors were 
detected. This is an information-only field; it is not user-configurable.
Parameter
User Options
Notes
Default
BERT
off     mark     space     1:1     1:7 3:24 qrss prb11 
prb15 prb20
off
DIR
net user
net
SYNC
information only–no user options
BE
information only–no user options
ES
information only–no user options
SES
information only–no user options
CSES
information only–no user options
OSS
information only–no user options
BER
information only–no user options
ELAP
information only–no user options
LB ST
information only–no user options