Zhone IMACS-200 ユーザーズマニュアル

ページ / 294
11-2 
Alarm Ports
Model No.
Running Head
Alarm port User Screens and Settings
Alarm ports
11.2
Alarm port User Screens and Settings
11.2.1 Alarm Filter Screen Sensor Setting
First, make sure the master setting for all alarm sensors is set properly as the SENSOR variable 
in the Alarm Filter Screen. To set this variable, first select Alarms from the System Main 
Screen, then choose Filters. This will display a list of alarm filters, as shown in Figure 11-1.
In this menu, use the arrow keys to highlight the first column of the SENSOR line. Pressing 
<Enter> displays the options ignorelog, and report. The option chosen here will act as the 
highest-level option for all alarm port sensors. If this variable is set to ignoreany alarm 
conditions on the alarm port will be ignored
, even if you set them up individually to log or 
report.
Likewise, if you set this variable to log, all sensors on the Alarm port that are set to anything 
other than ignore will be logged but not reported. For this reason, it is crucial that the 
SENSOR variable be set to report (see Figure 11-1). The following screen is the default alarm 
filter settings that are set on the IMACS-200.
Figure 11-1.Alarm Filter Screen
11.2.2 Alarm Ports Main Screen
Figure 11-2 shows the Alarm level from the Main Screen. To go to this screen, highlight the 
ALM area in the System Main Screen and press <Enter>.