Zhone IMACS-200 ユーザーズマニュアル

ページ / 294
System Installation
2-13 
System Installation
Power and Grounding on the IMACS-200
2.5
Power and Grounding on the IMACS-200
2.5.1
Power Supply and Ringing Generator
The power supply and ringing generator system can consist of up to two power supplies, and 
has one on-board ringing generator. The IMACS-200 comes with the proper power supplies 
factory-assembled depending on the ordering information provided at the time of purchase. 
2.5.1.1
Ringing Generator
The Ringing Generator on the IMACS-200 outputs 86Vrms at 20Hz. That is the output if 
ringing into a 1 to 4 REN load. If the load increases, the built-in overload protection will 
reduce the output voltage in steps as shown in Table 2-11.
This ability inherent in the IMACS-200 provides continuous service up to 12 North American 
REN loads without distortion.
Following is more detailed information regarding the power inputs.
Table 2-11. Ringing Generator Load Versus REN
Output Ringing Amplitude
Load[1REN = 
6930Ohms and 8 
picoFarads]
86 Vrms
4REN
75 Vrms
5REN
70 Vrms
6REN
60 Vrms
8REN
50 Vrms
10REN
45 Vrms
12REN
Short Circuit Protection Active
>>12REN