System Configuration and Operation
3.7.2
Alarm Filter Settings
You can set filters for each alarm so that the alarm reports occurrences in a number of different 
ways. Figure 3-11 shows the Alarm Filters screen, which is accessed by pressing "f" (Filters 
command) on the Alarm Screen.
Figure 3-11.Alarm Filters Screen
The first column of the Alarm Filters Screen is the alarm abbreviation that appears when an 
alarm is generated. The second column is the associated full name of each alarm. Table 3-2 
describes each alarm appearing in the Alarm Filters Screen.
The third column contains the filters ignore, log, and report. Set the filter to ignore if you 
want the system to ignore the alarm. Or, set it to log if you want the system to show the alarm 
report on the screen and also log it into the Alarm History, as described later in this chapter.
Set the filter to report if you want the system to send (report) the alarm indication to a remote 
device. With this setting, the system will also display the alarm report on the screen and log it 
into the Alarm History.
The fourth column of the Alarm Filters Screen contains the filter modifiers infominor
major, and crit. This column specifies a level of importance (information only, minor alarm, 
major alarm, or critical alarm) for each alarm. These settings are described later in this chapter.
The last column sets the alarm cutoff (ACO) to aco-off or aco-on. These settings are explained 
later in this chapter.
The filter in the third column takes precedence over its modifier. If, for instance, you have an 
alarm filter set to ignore, the setting of the modifier as infominormajor, or crit will be 
ignored. Refer to system specifications section in this manual for alarms and their meanings.