VIKING TECHNICAL SUPPORT 1.800.908.0884
2 5
Initial Settings
NOTE:
Installing a shunt or jumper on the pins will activate the feature.
CONTROL BOARD SETUP
“Fail Safe/Secure”
During complete power
failure, including battery
power; determines the force
required to manually move
the gate.
• Fail Safe Mode:
failure, including battery
power; determines the force
required to manually move
the gate.
• Fail Safe Mode:
By removing the wire-
jumper plug from the “Fail
Safe/Secure” connector:
The gate can move
manually with a relatively
low amount of force.
jumper plug from the “Fail
Safe/Secure” connector:
The gate can move
manually with a relatively
low amount of force.
• Fail Secure Mode:
By inserting the wire-
jumper plug into the “Fail
Safe/Secure” connector:
The gate will not move
manually.
jumper plug into the “Fail
Safe/Secure” connector:
The gate will not move
manually.
!
IMPORTANT:
Regardless of the power failure options chosen, the gate can be moved
manually with a relatively low amount of force by following the steps for “Manual
Release” as outlined at on page 11.
Release” as outlined at on page 11.
“Sync”
Used only in conjunction with
the Viking Barrier gate operator model
B-12. Activating this feature allows for
synchronized operation with the B-12
operator. See page 35.
B-12. Activating this feature allows for
synchronized operation with the B-12
operator. See page 35.
“Auto Open” - Power Failure Option
Opens the gate automatically during
power failure. Resumes normal operation
when power is restored.
power failure. Resumes normal operation
when power is restored.
“Pre-Warning”
Initiates two options for
an audio or visual warning 3 seconds
prior to gate motion and will continue:
prior to gate motion and will continue:
1. Until gate reaches closed limit:
“Magnetic Lock” terminals provide a
contact between “COM” and “N.O”.
contact between “COM” and “N.O”.
2. Until gate reaches either limit:
“AUX. PWR” terminals provide 24VDC.
“EXT”
Available for future developments.
“Last Open” - Power Failure Option
Opens the gate automatically when the
battery backup voltage is critically low.
battery backup voltage is critically low.