Siemens Network Hardware D410 ユーザーズマニュアル

ページ / 150
 
Commissioning (software) 
 
4.6 Using drive-related I/Os by SIMOTION 
D410 
Commissioning Manual, 08/2008 Edition 
105
 
Table 4-10  Global measuring inputs, configuration of the Measuring Input TO 
Axis measuring system no.  Under axis measuring system number, enter the number of the used 
encoder system (namely, encoder 1, 2 or 3). Encoder system 1 is the 
default setting. 
Global measuring 
Activate the checkbox when a global measuring input is used. 
Enter here the logical HW address and the bit number of the used 
input. 
Start address message frame 39x + 3, bit 1 for input DI/DO 9 
Start address message frame 39x + 3, bit 2 for input DI/DO 10 
Logical hardware address 
and bit number: 
Start address message frame 39x + 3, bit 3 for input DI/DO 11 
Detailed information is contained in the 
SIMOTION Motion Control Output Cams and 
Measuring Outputs
 Function Manual.  
4.6.8 
Outputs of cam outputs and probe inputs on TM15/TM17 High Feature 
Quantity framework for TM15/TM17 High Feature 
The TM15/TM17 High Feature Terminal Modules can be used to extend the number of 
outputs for cam outputs and probe inputs that can be installed. 
●  TM15, maximum 24 outputs for cam outputs / probe inputs 
●  TM17 High Feature, maximum 16 outputs for cam outputs / probe inputs 
Additional references 
Detailed information for the configuration is contained in the following documents 
●  SIMOTION Output Cams and Measuring Inputs Function Manual 
●  TM15/TM17 High Feature Terminal Modules Commissioning Manual