Siemens Network Hardware D410 ユーザーズマニュアル

ページ / 150
 
Commissioning (software) 
 
4.8 Creating a DMC20 
D410 
Commissioning Manual, 08/2008 Edition 
107
 
4.8 
Creating a DMC20 
4.8.1 
DMC20 hub properties 
DRIVE-CLiQ hub properties 
The DMC20 DRIVE-CLiQ hub can be used to extend the number of DRIVE-CLiQ interfaces 
and to configure a star topology. You must increase the number of DRIVE-CLiQ interfaces if 
connecting the following additional components:  
●  Direct measuring systems 
●  Terminal modules 
●  Reduction of the network hierarchy levels 
A star topology has the following advantages: 
●  The components can operate as end node of your segment. 
●  Line communication is not affected. 
Application examples 
Encoder expansion and hot-plugging are typical applications implemented by means of a 
DRIVE-CLiQ hub. 
●  An encoder expansion involves integration of direct measuring systems. These are 
installed in the control cabinet directly at the machine. Several encoders can be 
connected to the same hub. 
Note: SIMOTION D410 has just one DRIVE-CLiQ interface. You can use the DMC20 to 
evaluate the motor encoder and an additional encoder by means of SMx. 
●  Hot plugging is the option for changing motor components while in operation. These 
components are connected to a star topology using a DRIVE-CLiQ hub. This setup allows 
their deactivation without impairing downstream components. 
Additional references 
Information pertaining to the DMC20 DRIVE-CLiQ hub is available in the 
SIMOTION D410
 
Manual.